Characteristics measurement of Baghdad University radio telescope for hydrogen emission line

Uday E Jallod, Kamal M. Abood
{"title":"Characteristics measurement of Baghdad University radio telescope for hydrogen emission line","authors":"Uday E Jallod, Kamal M. Abood","doi":"10.1063/1.5138521","DOIUrl":null,"url":null,"abstract":"The aim of this paper is to measure the characteristics properties of 3 m radio telescope that installed inside Baghdad University campus. The measurements of this study cover some of the fundamental parameters at 1.42 GHz. These parameters concentrated principally on, the system noise temperature, signal to noise ratio and sensitivity, half power beam width, aperture efficiency, and effective area. These parameters are estimated via different radio sources observation like Cas-A, full moon, sky background, and solar drift scan observations. From the results of these observations, these parameters are found to be approximately 64 K, 1.2, 0.9 Jansky, 3.7°, 0.54, and 3.8 m2 respectively. The parameters values have vital affect to quantitative assessment of our radio telescope and they are in a good correlation with the results presented in the literature.The aim of this paper is to measure the characteristics properties of 3 m radio telescope that installed inside Baghdad University campus. The measurements of this study cover some of the fundamental parameters at 1.42 GHz. These parameters concentrated principally on, the system noise temperature, signal to noise ratio and sensitivity, half power beam width, aperture efficiency, and effective area. These parameters are estimated via different radio sources observation like Cas-A, full moon, sky background, and solar drift scan observations. From the results of these observations, these parameters are found to be approximately 64 K, 1.2, 0.9 Jansky, 3.7°, 0.54, and 3.8 m2 respectively. The parameters values have vital affect to quantitative assessment of our radio telescope and they are in a good correlation with the results presented in the literature.","PeriodicalId":186251,"journal":{"name":"TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY: TMREES19Gr","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY: TMREES19Gr","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/1.5138521","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The aim of this paper is to measure the characteristics properties of 3 m radio telescope that installed inside Baghdad University campus. The measurements of this study cover some of the fundamental parameters at 1.42 GHz. These parameters concentrated principally on, the system noise temperature, signal to noise ratio and sensitivity, half power beam width, aperture efficiency, and effective area. These parameters are estimated via different radio sources observation like Cas-A, full moon, sky background, and solar drift scan observations. From the results of these observations, these parameters are found to be approximately 64 K, 1.2, 0.9 Jansky, 3.7°, 0.54, and 3.8 m2 respectively. The parameters values have vital affect to quantitative assessment of our radio telescope and they are in a good correlation with the results presented in the literature.The aim of this paper is to measure the characteristics properties of 3 m radio telescope that installed inside Baghdad University campus. The measurements of this study cover some of the fundamental parameters at 1.42 GHz. These parameters concentrated principally on, the system noise temperature, signal to noise ratio and sensitivity, half power beam width, aperture efficiency, and effective area. These parameters are estimated via different radio sources observation like Cas-A, full moon, sky background, and solar drift scan observations. From the results of these observations, these parameters are found to be approximately 64 K, 1.2, 0.9 Jansky, 3.7°, 0.54, and 3.8 m2 respectively. The parameters values have vital affect to quantitative assessment of our radio telescope and they are in a good correlation with the results presented in the literature.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
巴格达大学射电望远镜对氢发射线的特性测量
本文的目的是测量安装在巴格达大学校园内的3米射电望远镜的特性。本研究的测量涵盖了1.42 GHz的一些基本参数。这些参数主要集中在系统噪声温度、信噪比和灵敏度、半功率波束宽度、孔径效率和有效面积。这些参数是通过不同的射电源观测,如Cas-A、满月、天空背景和太阳漂移扫描观测来估计的。根据这些观测结果,这些参数分别约为64 K、1.2、0.9 Jansky、3.7°、0.54和3.8 m2。这些参数值对射电望远镜的定量化评价有重要影响,且与文献结果具有良好的相关性。本文的目的是测量安装在巴格达大学校园内的3米射电望远镜的特性。本研究的测量涵盖了1.42 GHz的一些基本参数。这些参数主要集中在系统噪声温度、信噪比和灵敏度、半功率波束宽度、孔径效率和有效面积。这些参数是通过不同的射电源观测,如Cas-A、满月、天空背景和太阳漂移扫描观测来估计的。根据这些观测结果,这些参数分别约为64 K、1.2、0.9 Jansky、3.7°、0.54和3.8 m2。这些参数值对射电望远镜的定量化评价有重要影响,且与文献结果具有良好的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Theoretical simulation model of a proton exchange membrane fuel cell Study the effect of nanoic indium oxide (In2O3) on electrical properties of ZnO- based varistor Synthesis of copper oxide nanoparticles (CuO-NPs) and its evaluation of antibacterial activity against P. aeruginosa biofilm gene’s Comparative analysis regarding burning process for different fuels in hybrid rocket engines Antibacterial activity of chitosan/PAN blend prepared at different ratios
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1