Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States

Liangyu Shi, Xiaobing Liu, M. Qu, Guodong Liu, Zhi Li
{"title":"Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States","authors":"Liangyu Shi, Xiaobing Liu, M. Qu, Guodong Liu, Zhi Li","doi":"10.1115/1.4051992","DOIUrl":null,"url":null,"abstract":"\n Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Overall, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by −12% to 2%. The nationwide total electricity consumption would be reduced by 9%.","PeriodicalId":326594,"journal":{"name":"ASME Journal of Engineering for Sustainable Buildings and Cities","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASME Journal of Engineering for Sustainable Buildings and Cities","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4051992","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Overall, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by −12% to 2%. The nationwide total electricity consumption would be reduced by 9%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用热能储存集成地源热泵系统重塑美国电力需求的潜力
每年,美国超过20%的发电量用于满足住宅和商业建筑的热需求(如空间制冷、空间供暖和水加热)。将热能储存(TES)与建筑物的HVAC系统集成有可能重塑建筑物的电力负荷概况,并缓解可再生能源发电与建筑物需求之间的不匹配。提出了一种新型地源热泵系统与地下储热系统相结合,在满足建筑热需求的同时平衡建筑用电需求。本研究以自下而上的方法评估拟议系统的潜在影响。量化对不同电力市场电力需求的影响。结果表明,在现有电网的容量范围内,该系统在不同批发市场的最大渗透率可从51%到100%不等。总的来说,约有4600万户独立住宅可以改造成拟议的系统,而不会增加相应市场的年度峰值需求。通过以最大渗透率实施该系统,电网级夏季高峰需求可减少9.1%至18.2%。同时,在电网层面,年用电量将变化- 12%至2%。全国总用电量将减少9%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impact of Building Design and Operating Strategies on Urban Heat Island Effects Part II: Sensitivity Analysis ASSESSING ENERGY SAVINGS: A COMPARATIVE STUDY OF REFLECTIVE ROOF COATINGS IN FOUR USA CLIMATE ZONES AN ELEMENTARY APPROACH TO EVALUATING THE THERMAL SELF-SUFFICIENCY OF RESIDENTIAL BUILDINGS WITH THERMAL ENERGY STORAGE A PROPOSED METHOD AND CASE STUDY OF WASTE HEAT RECOVERY IN AN INDUSTRIAL APPLICATION Impact of Building Operating Strategies on Urban Heat Island Effects Part I: Model Development and Validation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1