The research of a rectifier type high temperature superconducting fault current limiter

Zhu Qing, Zhou Youqing, Hu Juan
{"title":"The research of a rectifier type high temperature superconducting fault current limiter","authors":"Zhu Qing, Zhou Youqing, Hu Juan","doi":"10.1109/ICEMS.2001.970760","DOIUrl":null,"url":null,"abstract":"Superconducting techniques will be used in electrical power systems widely. Installing a high temperature superconducting fault current limiter (HSCFCL) in electrical power systems is an effective measure to limit the fault short circuit current and to reduce breaking capacity of the circuit breaker. In this paper, the scope of critical current of a superconductor is defined. A rectifier type HSCFCL is selected. The fault current-limiting duration of HSCFCL is determined and its principle is sized up. At the end of this paper, the creative characteristics of this scheme are raised.","PeriodicalId":143007,"journal":{"name":"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2001-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMS.2001.970760","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Superconducting techniques will be used in electrical power systems widely. Installing a high temperature superconducting fault current limiter (HSCFCL) in electrical power systems is an effective measure to limit the fault short circuit current and to reduce breaking capacity of the circuit breaker. In this paper, the scope of critical current of a superconductor is defined. A rectifier type HSCFCL is selected. The fault current-limiting duration of HSCFCL is determined and its principle is sized up. At the end of this paper, the creative characteristics of this scheme are raised.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
整流型高温超导故障限流器的研究
超导技术将在电力系统中得到广泛应用。在电力系统中安装高温超导故障限流器(HSCFCL)是限制故障短路电流和降低断路器分断能力的有效措施。本文定义了超导体临界电流的范围。选用整流器型HSCFCL。确定了HSCFCL的故障限流时间,确定了其原理。最后,提出了该方案的创新特点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design principles of magnetically controlled reactor The mathematical model and field-oriented control for 15-phase brushless direct current motor with an opened phase A novel starting method for the sensorless salient-pole brushless DC motors Field-circuit optimum combination for permanent magnet machine design and analysis Design and research on variable-frequency speed-regulating electric power dynamometer motor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1