Characterization of Electromagnetic Wave Propagation in Transformer for PD Detection Analysis

Thanadol Tiengthong, Adi Mahmud Jaya Marindra, N. Pattanadech, S. Promwong
{"title":"Characterization of Electromagnetic Wave Propagation in Transformer for PD Detection Analysis","authors":"Thanadol Tiengthong, Adi Mahmud Jaya Marindra, N. Pattanadech, S. Promwong","doi":"10.1109/iceast55249.2022.9826332","DOIUrl":null,"url":null,"abstract":"The characterization of transformer wall effects a big problem regarding to the partial discharge, which caused substantial business losses and partial discharge analysis. Previously, there were methods of examination and evaluation using ultrasonic and acoustic waves, for this thesis saw the importance of having studied and done. Test the transmission of electromagnetic waves in a power transformer. The vector network analyzer was used to measure and record the results. A microstrip patch antenna was used to evaluate the experimental measurements on the designed transformer wall at different locations. The results obtained from the experiments will be analyzed, evaluated, and compared to the transfer function of the electromagnetic wave in the transformer. Considering the transfer function, power delay profile, and path loss, in the cases of no obstruction and obstruction from the evaluation and comparative consideration. Studies and experiments show that the data obtained measuring electromagnetic wave characteristics in transformers are guidelines in the study and analysis of partial discharges in the transformer. And primary data for the future analysis of partial discharges in the transformer.","PeriodicalId":441430,"journal":{"name":"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/iceast55249.2022.9826332","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The characterization of transformer wall effects a big problem regarding to the partial discharge, which caused substantial business losses and partial discharge analysis. Previously, there were methods of examination and evaluation using ultrasonic and acoustic waves, for this thesis saw the importance of having studied and done. Test the transmission of electromagnetic waves in a power transformer. The vector network analyzer was used to measure and record the results. A microstrip patch antenna was used to evaluate the experimental measurements on the designed transformer wall at different locations. The results obtained from the experiments will be analyzed, evaluated, and compared to the transfer function of the electromagnetic wave in the transformer. Considering the transfer function, power delay profile, and path loss, in the cases of no obstruction and obstruction from the evaluation and comparative consideration. Studies and experiments show that the data obtained measuring electromagnetic wave characteristics in transformers are guidelines in the study and analysis of partial discharges in the transformer. And primary data for the future analysis of partial discharges in the transformer.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
变压器中电磁波传播特性的PD检测分析
变压器壁的表征对局部放电的影响很大,造成了大量的业务损失和局部放电分析。在此之前,有超声波和声波检测和评价的方法,因此本文的研究和做的重要性。测试电磁波在电力变压器中的传输。使用矢量网络分析仪测量并记录结果。利用微带贴片天线对设计的变压器壁在不同位置上的实验测量结果进行了评估。从实验中得到的结果将被分析、评估,并与变压器中的电磁波传递函数进行比较。综合考虑传递函数、功率延时曲线和路径损耗,在无阻碍和无阻碍的情况下进行评价和比较考虑。研究和实验表明,测量变压器电磁波特性所获得的数据对变压器局部放电的研究和分析具有指导意义。为今后变压器局部放电的分析提供了初步数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Investigation of Wireless Body Area Network Localization Based on Measurement Data The Misconception of Relational Database and the ACID Properties The Bandwidth Verification of on-site UHF Sensor for Partial Discharge Measurement Online PD Measurement by Detecting the Pulsed Compensating Current in High Voltage Equipment Measuring System for Parameter Evaluation of Full Lightning Impulse Voltage Waveform
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1