Atrial Fibrillation Detection Algorithm with Ratio Variation-Based Features

Chen-Wei Huang, Jian-Jiun Ding
{"title":"Atrial Fibrillation Detection Algorithm with Ratio Variation-Based Features","authors":"Chen-Wei Huang, Jian-Jiun Ding","doi":"10.1109/ECICE55674.2022.10042909","DOIUrl":null,"url":null,"abstract":"A two-layer analysis approach of the atrial fibrillation episode detection algorithm tested in the MIT-BIH atrial fibrillation database (MIT-BIH AFDB) is proposed in the paper. We use several methodologies, including gradient varying weighted filter, template matched filter, adaptive threshold, and sliding window to accurately extract the locations and amplitudes of P, Q, R, S, and T peaks, P wave width, and QS width in an ECG complex as basic features. On the other hand, most existing works utilize features of RR intervals, a difference of RR intervals, or amplitude of P wave for AF episode detection. In the proposed algorithm, we exploit the ratio concept to transform basic features into ratio-based features with relative relations because those features are much easier to measure the irregularity of RR intervals and P wave absence precisely in atrial fibrillation episodes. Furthermore, we apply the innovative definition of ratio variation-based features to generate robust and qualitative feature extraction sets. Finally, a rule-based ratio variation hypothesis classifier with techniques of weighted coefficient function, product-form score function, Gini index function, and Gini splitting function is adopted. The performance result of the proposed algorithm, trained and tested in the MIT-BIH AF database, achieves an average sensitivity value of 99.272% and an average specificity value of 98.495%, respectively. The accuracy is superior to that of other various AF episode detection algorithms.","PeriodicalId":282635,"journal":{"name":"2022 IEEE 4th Eurasia Conference on IOT, Communication and Engineering (ECICE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 4th Eurasia Conference on IOT, Communication and Engineering (ECICE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECICE55674.2022.10042909","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A two-layer analysis approach of the atrial fibrillation episode detection algorithm tested in the MIT-BIH atrial fibrillation database (MIT-BIH AFDB) is proposed in the paper. We use several methodologies, including gradient varying weighted filter, template matched filter, adaptive threshold, and sliding window to accurately extract the locations and amplitudes of P, Q, R, S, and T peaks, P wave width, and QS width in an ECG complex as basic features. On the other hand, most existing works utilize features of RR intervals, a difference of RR intervals, or amplitude of P wave for AF episode detection. In the proposed algorithm, we exploit the ratio concept to transform basic features into ratio-based features with relative relations because those features are much easier to measure the irregularity of RR intervals and P wave absence precisely in atrial fibrillation episodes. Furthermore, we apply the innovative definition of ratio variation-based features to generate robust and qualitative feature extraction sets. Finally, a rule-based ratio variation hypothesis classifier with techniques of weighted coefficient function, product-form score function, Gini index function, and Gini splitting function is adopted. The performance result of the proposed algorithm, trained and tested in the MIT-BIH AF database, achieves an average sensitivity value of 99.272% and an average specificity value of 98.495%, respectively. The accuracy is superior to that of other various AF episode detection algorithms.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于比值变化特征的房颤检测算法
本文提出了在MIT-BIH房颤数据库(MIT-BIH AFDB)中测试的房颤发作检测算法的两层分析方法。采用梯度变加权滤波、模板匹配滤波、自适应阈值和滑动窗口等方法,准确提取心电信号中P、Q、R、S和T峰的位置和幅度、P波宽度和QS宽度作为基本特征。另一方面,现有的研究大多利用RR间隔、RR间隔差或P波振幅的特征来检测AF发作。在该算法中,我们利用比率概念将基本特征转化为具有相对关系的基于比率的特征,因为这些特征更容易精确地测量房颤发作时RR间隔的不规则性和P波缺失。此外,我们应用基于比率变化特征的创新定义来生成鲁棒性和定性的特征提取集。最后,采用加权系数函数、产品形式分数函数、基尼指数函数和基尼分裂函数等技术,建立了基于规则的比率变异假设分类器。在MIT-BIH AF数据库中进行训练和测试的性能结果表明,该算法的平均灵敏度值为99.272%,平均特异性值为98.495%。准确度优于其他各种AF事件检测算法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
License Plate Recognition Model For Tilt Correction Based on Convolutional Neural Network Quaternion Singular Spectrum Analysis of Pupillary Dynamics for Health Monitoring Trajectory Tracking Control of Autonomous Lawn Mower Based on ANSMC Task Scheduling with Makespan Minimization for Distributed Machine Learning Ensembles Socially Assistive Robots Assisting Older Adults in an Internet and Smart Healthcare Era: A Literature Review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1