{"title":"Implementation of ECG signal processing algorithms for removing baseline wander and electromyography interference","authors":"Changhsi Wu, Yanrong Zhang, Chengyo Hong, H. Chiueh","doi":"10.1109/ICCSN.2016.7586631","DOIUrl":null,"url":null,"abstract":"Implementation of ECG signal processing algorithms for removing baseline wander and electromyography (EMG) interference is proposed in this paper. First, Moving Average Filter (MAF) is used to remove the baseline wanders in ECG signal. Then the EMG components are detected and canceled by the Empirical Mode Decomposition (EMD). The Texas Instruments (TI) produced ADS1298 is chose to be the Analog Front-End (AFE) ECG capture chip which provides 8 measurement channels. The ARM series chips of STMicroelectronics produced STM32F429ZI is used as the computing core of signal processing which has operation frequency of up to 180MHz and is suitable for a large amount of data calculation as well as peripheral interface control.","PeriodicalId":158877,"journal":{"name":"2016 8th IEEE International Conference on Communication Software and Networks (ICCSN)","volume":"30 6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 8th IEEE International Conference on Communication Software and Networks (ICCSN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCSN.2016.7586631","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Implementation of ECG signal processing algorithms for removing baseline wander and electromyography (EMG) interference is proposed in this paper. First, Moving Average Filter (MAF) is used to remove the baseline wanders in ECG signal. Then the EMG components are detected and canceled by the Empirical Mode Decomposition (EMD). The Texas Instruments (TI) produced ADS1298 is chose to be the Analog Front-End (AFE) ECG capture chip which provides 8 measurement channels. The ARM series chips of STMicroelectronics produced STM32F429ZI is used as the computing core of signal processing which has operation frequency of up to 180MHz and is suitable for a large amount of data calculation as well as peripheral interface control.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
消除基线漫游和肌电图干扰的心电信号处理算法的实现
提出了一种消除基线漂移和肌电干扰的心电信号处理算法。首先,采用移动平均滤波(MAF)去除心电信号中的基线漂移;然后通过经验模态分解(EMD)检测并消除肌电分量。选择德州仪器(TI)生产的ADS1298作为模拟前端(AFE) ECG捕获芯片,提供8个测量通道。采用意法半导体公司生产的ARM系列芯片STM32F429ZI作为信号处理的计算核心,工作频率高达180MHz,适用于大量数据计算和外设接口控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Detecting sports fatigue from speech by support vector machine Error beacon filtering algorithm based on K-means clustering for underwater Wireless Sensor Networks Transmit beamforming optimization for energy efficiency maximization in downlink distributed antenna systems Research of 3D face recognition algorithm based on deep learning stacked denoising autoencoder theory Improved propagator method for joint angle and Doppler estimation based on structured least squares
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1