Power Quality Analyzers Calibration on Harmonics of Voltage and Current by Reference Square Waveform Signal and Algorithm for Measurement ang Processing

P. Tzvetkov, K. Galabov, A. Serov, I. Kodjabashev
{"title":"Power Quality Analyzers Calibration on Harmonics of Voltage and Current by Reference Square Waveform Signal and Algorithm for Measurement ang Processing","authors":"P. Tzvetkov, K. Galabov, A. Serov, I. Kodjabashev","doi":"10.1109/MMA52675.2021.9610939","DOIUrl":null,"url":null,"abstract":"The possibility for calibrating Power Quality Analyzer by harmonics is presented by using a reference square waveform signal. Based on the calibration model, a control algorithm is synthesized of the calibration measurement procedures and the processing of the uncertainty of the calibration results. Results from the calibration of the Fluke 435 analyzer with the Metrix CX1651 calibrator on voltage and current harmonics are presented, which confirm the possibilities of using the reference square waveform signal.","PeriodicalId":287017,"journal":{"name":"2021 XXXI International Scientific Symposium Metrology and Metrology Assurance (MMA)","volume":"220 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 XXXI International Scientific Symposium Metrology and Metrology Assurance (MMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MMA52675.2021.9610939","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The possibility for calibrating Power Quality Analyzer by harmonics is presented by using a reference square waveform signal. Based on the calibration model, a control algorithm is synthesized of the calibration measurement procedures and the processing of the uncertainty of the calibration results. Results from the calibration of the Fluke 435 analyzer with the Metrix CX1651 calibrator on voltage and current harmonics are presented, which confirm the possibilities of using the reference square waveform signal.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电能质量分析仪用参考方波信号标定电压和电流谐波及测量和处理算法
提出了利用参考方波信号对电能质量分析仪进行谐波校准的可能性。在标定模型的基础上,综合了标定测量过程和标定结果不确定度处理的控制算法。给出了用Metrix CX1651校准器对Fluke 435分析仪进行电压和电流谐波校准的结果,证实了使用参考方波信号的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Ensemble Approach Based on Bagging and Boosting for Identification the Computer System State Analysis and evaluation of data available in a medical laboratory at estimating measurement uncertainty Measurement with intelligent measuring system of PCB deformation when separating modules from a panel Criterion Assessment of the Probability of Deviation of Objects from the Normal State Application of Sliding DFT Filtration to Improve Frequency Measurement Accuracy of Zero Crossing Technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1