Comparison of two fast reconstruction methods for a cylindrical PET camera

M. Grégoire, D. Chesler
{"title":"Comparison of two fast reconstruction methods for a cylindrical PET camera","authors":"M. Grégoire, D. Chesler","doi":"10.1109/NSSMIC.1992.301011","DOIUrl":null,"url":null,"abstract":"The authors compare the accuracy and precision of two fast reconstruction methods for a cylindrical PET (positron emission tomography) camera. One method is based on the estimation of the missing data; the other uses different amounts of data to reconstruct each slice. Both methods are implemented in the frequency domain and run on realistic data in less than two hours. Their intrinsic quality is quite similar. In the presence of statistical noise, there is no significant difference between the methods. One could therefore prefer to use the interpolative reconstruction for a small centered activity distribution like a receptor study, while reserving the Favor procedure for a large distribution pattern like a cerebral blood flow study. This study has been carried out on the model of the cylindrical PET camera under development at the Massachusetts General Hospital.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1992.301011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The authors compare the accuracy and precision of two fast reconstruction methods for a cylindrical PET (positron emission tomography) camera. One method is based on the estimation of the missing data; the other uses different amounts of data to reconstruct each slice. Both methods are implemented in the frequency domain and run on realistic data in less than two hours. Their intrinsic quality is quite similar. In the presence of statistical noise, there is no significant difference between the methods. One could therefore prefer to use the interpolative reconstruction for a small centered activity distribution like a receptor study, while reserving the Favor procedure for a large distribution pattern like a cerebral blood flow study. This study has been carried out on the model of the cylindrical PET camera under development at the Massachusetts General Hospital.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
圆柱形PET相机两种快速重建方法的比较
比较了圆柱正电子发射断层成像(PET)相机两种快速重建方法的准确度和精密度。一种方法是基于缺失数据的估计;另一种方法使用不同数量的数据来重建每个切片。这两种方法都是在频域中实现的,并且在不到两个小时的时间内运行在实际数据上。它们的内在品质非常相似。在存在统计噪声的情况下,两种方法之间没有显著差异。因此,对于像受体研究这样的小中心活动分布,人们可能更倾向于使用插值重建,而对于像脑血流研究这样的大分布模式,则保留偏好程序。这项研究是在麻省总医院正在开发的圆柱形PET相机模型上进行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Results in online data processing in the data acquisition system of the ALEPH TPC Practical evaluation of several cone beam orbits for SPECT Model based scatter correction in three dimensions (positron emission tomography) Macintosh software for simulating resolution and scatter effects in PET Testing fast ADC's at sample rates between 20 and 140 MSPS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1