{"title":"Power quality factor improvement using shunt active power line conditioner","authors":"M. Nagarjuna, P. C. Panda, A. Sandeep","doi":"10.1109/ICACCCT.2014.7019475","DOIUrl":null,"url":null,"abstract":"This paper describes an improvement method of power quality using shunt active power line conditioner (APLC) for a three phase supply system feeding three phase unbalanced non-linear load. A control algorithm is presented for an APLC to compensate harmonics and unbalance factor. Sensing load currents, dc bus voltages compute reference currents of APLC. APLC driving signals are produced with the reference signals via a hysteresis band current controller. MATLAB/simulink power system toolbox is used to simulate the proposed system. The proposed method restricts both THD and unbalance factor of input currents and a power quality factor is designated which integrally reflects the two quality aspects (i.e., harmonic and unbalance factor) before and after compensation. Power quality factor improvement with the proposed shunt APLC has been verified by the simulation results.","PeriodicalId":239918,"journal":{"name":"2014 IEEE International Conference on Advanced Communications, Control and Computing Technologies","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Conference on Advanced Communications, Control and Computing Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICACCCT.2014.7019475","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
This paper describes an improvement method of power quality using shunt active power line conditioner (APLC) for a three phase supply system feeding three phase unbalanced non-linear load. A control algorithm is presented for an APLC to compensate harmonics and unbalance factor. Sensing load currents, dc bus voltages compute reference currents of APLC. APLC driving signals are produced with the reference signals via a hysteresis band current controller. MATLAB/simulink power system toolbox is used to simulate the proposed system. The proposed method restricts both THD and unbalance factor of input currents and a power quality factor is designated which integrally reflects the two quality aspects (i.e., harmonic and unbalance factor) before and after compensation. Power quality factor improvement with the proposed shunt APLC has been verified by the simulation results.