Vertical standing copper nanowires for electrochemical sensor of nitrate in water

B. Patella, R. Russo, G. Aiello, C. Sunseri, R. Inguanta
{"title":"Vertical standing copper nanowires for electrochemical sensor of nitrate in water","authors":"B. Patella, R. Russo, G. Aiello, C. Sunseri, R. Inguanta","doi":"10.1109/FLEPS49123.2020.9239449","DOIUrl":null,"url":null,"abstract":"Nitrogen, in the forms of nitrate (NO3-), nitrite, or ammonium, is a nutrient needed for plant growth and it is a common constituent of fertilizers [1]. When fertilizers are overused, they contaminate the ground water and then the food chain. For humans, a low level of nitrate is advisable because it increases the blood flow and has a good effect on both blood pressure and cardiovascular system. On the contrary, a high concentration of nitrate can be dangerous for humans. Nitrate ions undergoes different chemical transformations (i.e. to nitrite ions by Escherichia coli) producing different nitrogen-based compound such as nitrite ions, nitric oxide and ammonia [2]. These chemicals lead to several problems such as cancer, neurodegenerative disease and gastritis. Furthermore, nitrate ions are responsible of the blu-baby disease because they oxide hemoblogin to methemoglobine which has a lower capability to transport oxygen [3]–[4]. Considering all these hazards, the Environmental Protection Agency (EPA) has fixed the maximum allowed concentration of nitrates in drinking water to 44 ppm [5]. Nowadays, nitrate ions quantification is performed by spectroscopy ensuring Limit Of Detection (LOD) in the ppb range [6]–[7]. However, this technique consists of hard procedure (conversion of nitrates to nitrite using cadmium or zinc salts) and requires skilled personnel. Furthermore, it lacks of sensitivity when coloured or opaque samples are analysed. Such disadvantages confine this technique to a lab-based analysis making impossible to detect nitrate ions in real time and/or in situ.","PeriodicalId":101496,"journal":{"name":"2020 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FLEPS49123.2020.9239449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Nitrogen, in the forms of nitrate (NO3-), nitrite, or ammonium, is a nutrient needed for plant growth and it is a common constituent of fertilizers [1]. When fertilizers are overused, they contaminate the ground water and then the food chain. For humans, a low level of nitrate is advisable because it increases the blood flow and has a good effect on both blood pressure and cardiovascular system. On the contrary, a high concentration of nitrate can be dangerous for humans. Nitrate ions undergoes different chemical transformations (i.e. to nitrite ions by Escherichia coli) producing different nitrogen-based compound such as nitrite ions, nitric oxide and ammonia [2]. These chemicals lead to several problems such as cancer, neurodegenerative disease and gastritis. Furthermore, nitrate ions are responsible of the blu-baby disease because they oxide hemoblogin to methemoglobine which has a lower capability to transport oxygen [3]–[4]. Considering all these hazards, the Environmental Protection Agency (EPA) has fixed the maximum allowed concentration of nitrates in drinking water to 44 ppm [5]. Nowadays, nitrate ions quantification is performed by spectroscopy ensuring Limit Of Detection (LOD) in the ppb range [6]–[7]. However, this technique consists of hard procedure (conversion of nitrates to nitrite using cadmium or zinc salts) and requires skilled personnel. Furthermore, it lacks of sensitivity when coloured or opaque samples are analysed. Such disadvantages confine this technique to a lab-based analysis making impossible to detect nitrate ions in real time and/or in situ.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于水中硝酸盐电化学传感器的立式立式铜纳米线
氮以硝酸盐(NO3-)、亚硝酸盐或铵的形式存在,是植物生长所需的营养物质,也是肥料的常见成分[1]。当化肥被过度使用时,它们会污染地下水,然后污染食物链。对人类来说,低水平的硝酸盐是可取的,因为它可以增加血液流动,对血压和心血管系统都有很好的影响。相反,高浓度的硝酸盐对人体是危险的。硝酸盐离子经过不同的化学转化(即被大肠杆菌转化为亚硝酸盐离子),产生不同的氮基化合物,如亚硝酸盐离子、一氧化氮和氨[2]。这些化学物质会导致一些问题,如癌症、神经退行性疾病和胃炎。此外,硝酸盐离子是蓝宝宝病的原因,因为它们将血红蛋白氧化为高铁血红蛋白,而高铁血红蛋白运输氧气的能力较低[3]-[4]。考虑到所有这些危害,美国环境保护署(EPA)将饮用水中硝酸盐的最大允许浓度定为44 ppm[5]。目前,硝酸盐离子定量是通过确保检出限(LOD)在ppb范围内的光谱学进行的[6]-[7]。然而,这种技术包括一个困难的程序(使用镉或锌盐将硝酸盐转化为亚硝酸盐),需要熟练的人员。此外,当分析有色或不透明样品时,它缺乏灵敏度。这些缺点限制了该技术的实验室为基础的分析,使得不可能在实时和/或原位检测硝酸盐离子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Wearable Wireless Power Transfer using Direct-Write Dispenser Printed Flexible Coils Binary Neural Network as a Flexible Integrated Circuit for Odour Classification Stretchable Wireless Sensor Skin for the Surface Monitoring of Soft Objects Assessing the Stability of Printed NWs by in situ SEM Characterisation Development of a Novel and Flexible MWCNT/PDMS Based Resistive Force Sensor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1