Accuracy Considerations for CW Radar Monitoring of Respiratory Motion

Mohammad Shadman Ishrak, V. Lubecke
{"title":"Accuracy Considerations for CW Radar Monitoring of Respiratory Motion","authors":"Mohammad Shadman Ishrak, V. Lubecke","doi":"10.23919/apmc55665.2022.9999973","DOIUrl":null,"url":null,"abstract":"The efficacy of different CW Doppler radar demodulation methods has been assessed based on performance in tracking idealized chest motion induced by respiratory activities. The arctangent, DACM, and ScD methods were tested for accoupled and dc-coupled data. A 2.4 GHz quadrature radar system was used to measure sinusoidal modeled chest motion produced using a mechanical mover. Based on the tracking of average rate, Pearson Correlation coefficient, and peak displacement, arctangent successfully performed both rate measurement and displacement tracking. DACM and ScD were sufficient for respiratory rate measurement but not for real-time displacement tracking.","PeriodicalId":219307,"journal":{"name":"2022 Asia-Pacific Microwave Conference (APMC)","volume":"17 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Asia-Pacific Microwave Conference (APMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/apmc55665.2022.9999973","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The efficacy of different CW Doppler radar demodulation methods has been assessed based on performance in tracking idealized chest motion induced by respiratory activities. The arctangent, DACM, and ScD methods were tested for accoupled and dc-coupled data. A 2.4 GHz quadrature radar system was used to measure sinusoidal modeled chest motion produced using a mechanical mover. Based on the tracking of average rate, Pearson Correlation coefficient, and peak displacement, arctangent successfully performed both rate measurement and displacement tracking. DACM and ScD were sufficient for respiratory rate measurement but not for real-time displacement tracking.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
连续波雷达监测呼吸运动的准确性考虑
不同的连续波多普勒雷达解调方法在跟踪由呼吸活动引起的理想胸部运动方面的效果进行了评估。对耦合和直流耦合数据进行了arctan、DACM和ScD方法的测试。2.4 GHz正交雷达系统用于测量由机械运动器产生的正弦模型胸部运动。基于平均速率、Pearson相关系数和峰值位移的跟踪,arctan成功地完成了速率测量和位移跟踪。DACM和ScD足以测量呼吸频率,但不能用于实时位移跟踪。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Beam Switching with Low Control Overhead for Millimeter-wave Communication A Wideband mmWave Array Antenna Package Based on Glass Integrated Passive Device A Study on 23.8-43 GHz CMOS Low-Power Ultra-Wideband Injection-Locked Frequency Multiplier with Transformer Input Optimal Design for Acoustic Wave SAW Extractor with Simple Matching Circuits Design of a Back-off Range Reconfigurable Sequential Power Amplifier with Doherty Type Load Modulation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1