Air-Conditioning in Telecom Installations with Lowest Energy Consumption

P. Schmidt
{"title":"Air-Conditioning in Telecom Installations with Lowest Energy Consumption","authors":"P. Schmidt","doi":"10.1109/INTLEC.1987.4794617","DOIUrl":null,"url":null,"abstract":"The air-conditioning of telecommunication centers is generally characterized by an all year high cooling load and by low outside air requirements. Therefore a chance would exist for the inexpensive so-called \"free cooling\" by use of colder outside air during most of the operating time throughout the year, if the expenditure for the then necessary humidification would not soon exceed the saved-up expenditure for cooling. This paper describes a new technical and operational concept to overcome this disadvantage of \"free cooling\", which allows savings of operating costs for air-conditioning up to 75%.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1987.4794617","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The air-conditioning of telecommunication centers is generally characterized by an all year high cooling load and by low outside air requirements. Therefore a chance would exist for the inexpensive so-called "free cooling" by use of colder outside air during most of the operating time throughout the year, if the expenditure for the then necessary humidification would not soon exceed the saved-up expenditure for cooling. This paper describes a new technical and operational concept to overcome this disadvantage of "free cooling", which allows savings of operating costs for air-conditioning up to 75%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
能源消耗最低的电信设施的空调
电信中心空调的特点是全年高冷负荷和低外部空气需求。因此,如果用于必要的加湿的支出不会很快超过节省下来的冷却支出,那么在全年大部分运行时间内,通过使用较冷的外部空气,就有可能实现廉价的所谓“自由冷却”。本文介绍了一种新的技术和操作概念,以克服“自然冷却”的缺点,使空调的运行成本节省高达75%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Power Supply System Application for a Large Telecom Data Center Moving the Power Equipment into the Switching Room Changes and Progress in Battery Technologies During the Last Decade, Outlook - Experiences as Viewed from America and Europe Telecommunication Power Supply with Programmable Logic Control Power Supply Systems for Remote, Unmanned Microwave Repeater Stations in Greenland
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1