ZnO Nanotip-based QCM Biosensors

Zheng Zhang, Hanhong Chen, J. Zhong, Ying Chen, Yicheng Lu
{"title":"ZnO Nanotip-based QCM Biosensors","authors":"Zheng Zhang, Hanhong Chen, J. Zhong, Ying Chen, Yicheng Lu","doi":"10.1109/FREQ.2006.275444","DOIUrl":null,"url":null,"abstract":"The medical diagnostics laboratories are showing an urgent need for accurate, fast and inexpensive biosensors. A zinc oxide (ZnO) nanotip-based quartz crystal microbalance (QCM) sensor is developed as a solution for accurate and inexpensive biosensors. The QCM sensor composed of single crystalline ZnO nanotips grown on top of a gold electrode using metal-organic chemical vapor deposition (MOCVD). Scanning electron microscopy (SEM) shows that the ZnO nanotips are uniformly aligned with their c-axis normal to the gold surface, giving a large surface area for sample up-taking. The ZnO nanotip coated QCM sensor shows a 10-time larger frequency shift than that of regular QCM sensors, when measuring the same DNA oligonucleotide (5'-AGAAAATCTTAGTGTC-3') solution. In addition, the hydrophilic behaviors of the nanotip array significantly reduce the required liquid volume for effective detection. 0.5 mul solution fully covers the QCM sensor area (0.2047 cm2), while a minimum of 16 mul liquid is required to cover a flat surface of the conventional QCM. ZnO nanotips show superhydrophilicity with a contact angle of ~0deg under ultraviolet (UV) illumination. The superhydrophilic sensor surface significantly boosts the solution taking up ability; therefore, enhances the sensitivity of the QCM sensor. The effects of ZnO nanostructure on the bulk acoustic wave (BAW) are also discussed","PeriodicalId":445945,"journal":{"name":"2006 IEEE International Frequency Control Symposium and Exposition","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Frequency Control Symposium and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FREQ.2006.275444","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

The medical diagnostics laboratories are showing an urgent need for accurate, fast and inexpensive biosensors. A zinc oxide (ZnO) nanotip-based quartz crystal microbalance (QCM) sensor is developed as a solution for accurate and inexpensive biosensors. The QCM sensor composed of single crystalline ZnO nanotips grown on top of a gold electrode using metal-organic chemical vapor deposition (MOCVD). Scanning electron microscopy (SEM) shows that the ZnO nanotips are uniformly aligned with their c-axis normal to the gold surface, giving a large surface area for sample up-taking. The ZnO nanotip coated QCM sensor shows a 10-time larger frequency shift than that of regular QCM sensors, when measuring the same DNA oligonucleotide (5'-AGAAAATCTTAGTGTC-3') solution. In addition, the hydrophilic behaviors of the nanotip array significantly reduce the required liquid volume for effective detection. 0.5 mul solution fully covers the QCM sensor area (0.2047 cm2), while a minimum of 16 mul liquid is required to cover a flat surface of the conventional QCM. ZnO nanotips show superhydrophilicity with a contact angle of ~0deg under ultraviolet (UV) illumination. The superhydrophilic sensor surface significantly boosts the solution taking up ability; therefore, enhances the sensitivity of the QCM sensor. The effects of ZnO nanostructure on the bulk acoustic wave (BAW) are also discussed
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于ZnO纳米尖端的QCM生物传感器
医学诊断实验室迫切需要准确、快速和廉价的生物传感器。为实现精确、廉价的生物传感器,研制了一种基于氧化锌纳米尖的石英晶体微平衡(QCM)传感器。采用金属有机化学气相沉积(MOCVD)技术,在金电极上生长单晶ZnO纳米尖组成QCM传感器。扫描电子显微镜(SEM)显示,ZnO纳米针尖与金表面垂直的c轴排列均匀,为样品的吸收提供了较大的表面积。当测量相同的DNA寡核苷酸(5'-AGAAAATCTTAGTGTC-3')溶液时,ZnO纳米尖端涂层的QCM传感器的频移比常规QCM传感器大10倍。此外,纳米尖端阵列的亲水性显著降低了有效检测所需的液体体积。0.5摩尔溶液完全覆盖QCM传感器区域(0.2047 cm2),而至少16摩尔液体需要覆盖传统QCM的平坦表面。在紫外光照射下,ZnO纳米针尖表现出超亲水性,接触角为~0度。传感器表面的超亲水性显著提高了吸液能力;因此,提高了QCM传感器的灵敏度。讨论了ZnO纳米结构对体声波(BAW)的影响
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optical Links and RF Distribution for Antenna Arrays A New OEO Design Using Optical Phase Modulation and Modulation Suppression A Low- Power Low-Voltage VCO with Wide Range Tuning Controlled by Adaptive Neural Network Low-voltage, Crystal Controlled Comb Spectrum Oscillator for Injection Locked STW Based Clocks with Improved Stability A Colpitts-Type Crystal Oscillator for Gigahertz Frequency
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1