T. Tamura, H. Sugeno, H. Sakurai, M. Noma, S. Gunji, Gertenbort
{"title":"An application of microstrip gas proportional counter for a X-ray polarimeter","authors":"T. Tamura, H. Sugeno, H. Sakurai, M. Noma, S. Gunji, Gertenbort","doi":"10.1109/NSSMIC.1995.504216","DOIUrl":null,"url":null,"abstract":"An application of a microstrip gas proportional counter to a X-ray polarimeter was investigated. Primary electron clouds produced by photoelectric absorption extend to the direction of electric vector of incident polarized X-ray and the direction of electron clouds to the microstrip plate (MS plate) affects the rise time of signal from MSGC. By using a test counter which mounted a MS plate, the characteristics of the rise time distributions of pulses from MSGC were investigated. The difference of the rise times between X-rays of /sup 55/Fe and /sup 241/Am sources was 71 nsec in Xe+methane (10%) with 0.4 atm. It reflects the difference of length of the trajectory between 5.9 keV X-rays and 29.8 keV photoelectrons ejected by photoabsorption. The detection of the rise time due to MSGC is available to a X-ray polarimeter.","PeriodicalId":409998,"journal":{"name":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1995.504216","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
An application of a microstrip gas proportional counter to a X-ray polarimeter was investigated. Primary electron clouds produced by photoelectric absorption extend to the direction of electric vector of incident polarized X-ray and the direction of electron clouds to the microstrip plate (MS plate) affects the rise time of signal from MSGC. By using a test counter which mounted a MS plate, the characteristics of the rise time distributions of pulses from MSGC were investigated. The difference of the rise times between X-rays of /sup 55/Fe and /sup 241/Am sources was 71 nsec in Xe+methane (10%) with 0.4 atm. It reflects the difference of length of the trajectory between 5.9 keV X-rays and 29.8 keV photoelectrons ejected by photoabsorption. The detection of the rise time due to MSGC is available to a X-ray polarimeter.