M. Knotek, F. Zezulka, Z. Simeu-Abazi, Z. Bouredji
{"title":"Robust control and its implementation in PLC for multi-hoist surface treatment lines","authors":"M. Knotek, F. Zezulka, Z. Simeu-Abazi, Z. Bouredji","doi":"10.1109/ICIT.2003.1290776","DOIUrl":null,"url":null,"abstract":"This paper presents a robust control approach for a class of production systems, the surface treatment lines. Our research is aimed at implementation techniques of robust control in PLC. A robust control is based on Petri Net modelling; scheduling sequence is described by PN model, equations for on-line control are derived by structural analysis. It helps us to explore the margins of capacity in order to cope with unpredictable perturbation of a sequence, whose interval of cyclic solution is calculated. The equations describing the PN model and the transport cycle of the PN are implemented in PLC by the technique proposed.","PeriodicalId":193510,"journal":{"name":"IEEE International Conference on Industrial Technology, 2003","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Conference on Industrial Technology, 2003","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2003.1290776","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper presents a robust control approach for a class of production systems, the surface treatment lines. Our research is aimed at implementation techniques of robust control in PLC. A robust control is based on Petri Net modelling; scheduling sequence is described by PN model, equations for on-line control are derived by structural analysis. It helps us to explore the margins of capacity in order to cope with unpredictable perturbation of a sequence, whose interval of cyclic solution is calculated. The equations describing the PN model and the transport cycle of the PN are implemented in PLC by the technique proposed.