Coils used in the Joule Balance at the NIM

Z. Zhang, Z. Li, B. Han, Y. Lu, S. Li, J. Xu, G. Wang, H. Gong
{"title":"Coils used in the Joule Balance at the NIM","authors":"Z. Zhang, Z. Li, B. Han, Y. Lu, S. Li, J. Xu, G. Wang, H. Gong","doi":"10.1109/CPEM.2014.6898423","DOIUrl":null,"url":null,"abstract":"In the Joule Balance at the National Institute of Metrology (NIM), the dynamic measurement during the coil movement is avoided. But for this method a rather large current in the primary coil is needed to generate the necessary magnetic field in the force weighing phase. Thus the coil heating becomes an obvious uncertainty contribution. To solve this problem, a new coil system, in which the ferromagnetic material is used to increase the magnetic field and then the coil heating is reduced obviously, is designed and tested recently. But the nonlinear characteristic of the ferromagnetic material brings the difficulty for the measurement. These problems and a solution are discussed in this paper.","PeriodicalId":256575,"journal":{"name":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","volume":"120 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2014.6898423","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In the Joule Balance at the National Institute of Metrology (NIM), the dynamic measurement during the coil movement is avoided. But for this method a rather large current in the primary coil is needed to generate the necessary magnetic field in the force weighing phase. Thus the coil heating becomes an obvious uncertainty contribution. To solve this problem, a new coil system, in which the ferromagnetic material is used to increase the magnetic field and then the coil heating is reduced obviously, is designed and tested recently. But the nonlinear characteristic of the ferromagnetic material brings the difficulty for the measurement. These problems and a solution are discussed in this paper.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在NIM焦耳天平中使用的线圈
在美国国家计量研究所(NIM)的焦耳天平中,避免了线圈运动过程中的动态测量。但是这种方法需要在初级线圈中有相当大的电流来产生称重阶段所需的磁场。因此,线圈加热成为一个明显的不确定性贡献。为了解决这一问题,最近设计并测试了一种新的线圈系统,该系统采用铁磁材料增加磁场,从而明显降低线圈的发热。但铁磁材料的非线性特性给测量带来了困难。本文对这些问题及解决方法进行了探讨。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Stability tests of electronic calibration units Dynamic range improvement of THz spectroscopy Realization of a traceable power quality calibration facility in full accordance with the IEC 61000-4-30 standard Uncertainty of communication signals measurement Determination of the Planck constant at the national institute of Standards and Technology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1