{"title":"Evaluation of medium voltage groundwall insulation exposed to high frequency pulse voltages","authors":"S. Haq, S. Jayaram, E. Cherney","doi":"10.1109/EEIC.2005.1566289","DOIUrl":null,"url":null,"abstract":"Class-F 4.0 kV coils designed for medium voltage induction motors are aged under combined thermal and electrical stresses of 500 h at a constant temperature of 120degC and 200 h at a constant temperature of 150degC and stressed electrically at 60 Hz and with steep-front unipolar pulses of 40 ns rise time. The changes in the partial discharge activity and the dissipation factor as a function of time are reported. During ageing, the temperature profiles are recorded with an infrared camera as a means for determining the highest stressed regions. The experimental results show that pulse ageing is very severe when compared to 60 Hz ageing, despite using a lower pulse voltage, although the location where damage occurs on the groundwall insulation is different","PeriodicalId":267510,"journal":{"name":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.2005.1566289","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Class-F 4.0 kV coils designed for medium voltage induction motors are aged under combined thermal and electrical stresses of 500 h at a constant temperature of 120degC and 200 h at a constant temperature of 150degC and stressed electrically at 60 Hz and with steep-front unipolar pulses of 40 ns rise time. The changes in the partial discharge activity and the dissipation factor as a function of time are reported. During ageing, the temperature profiles are recorded with an infrared camera as a means for determining the highest stressed regions. The experimental results show that pulse ageing is very severe when compared to 60 Hz ageing, despite using a lower pulse voltage, although the location where damage occurs on the groundwall insulation is different