Joao J. M. Santos, S. Palma, C. Esteves, Hugo Gamboa, João Pedro Oliveira, A. C. Roque
{"title":"An electrical model characterization of an electronic nose chemical sensor using a programmable system-on-a-chip based AFE","authors":"Joao J. M. Santos, S. Palma, C. Esteves, Hugo Gamboa, João Pedro Oliveira, A. C. Roque","doi":"10.1109/YEF-ECE55092.2022.9850098","DOIUrl":null,"url":null,"abstract":"The diagnosis of many diseases involves invasive detection methods, which are both painful and stressing for patients. In the last decades, the ever-growing development in electronic nose (E-Nose) technology made them great candidates for non-invasive disease detection methods. Such devices mimic the human olfactory system through a set of sensors which produce signals that can be associated with diseases. Recently, a class of low-cost and innovative ionogel sensors, developed by our group demonstrated their full applicability in E-Nose systems, opening a new and promising approach to the field. However, the operation of such sensor needs a background calibration phase which relies on the correct characterization and parameterization of the corresponding electrical sensor model.This paper proposes a model characterization methodology based on a set of frequency responses acquisitions of the sensor, under several humidity conditions. To obtain a flexible acquisition tool capable of acquiring accurate results, an analog front-end (AFE) circuit to interface with the interdigitated electrode (IDE) sensors is presented. Such AFE circuit is fully implemented using a programmable system-on-a-chip (PSoC), helping to reduce system size and cost. Lastly, a comparison between the electrical model and data acquired with the proposed system is presented.","PeriodicalId":444021,"journal":{"name":"2022 International Young Engineers Forum (YEF-ECE)","volume":"91 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Young Engineers Forum (YEF-ECE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/YEF-ECE55092.2022.9850098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The diagnosis of many diseases involves invasive detection methods, which are both painful and stressing for patients. In the last decades, the ever-growing development in electronic nose (E-Nose) technology made them great candidates for non-invasive disease detection methods. Such devices mimic the human olfactory system through a set of sensors which produce signals that can be associated with diseases. Recently, a class of low-cost and innovative ionogel sensors, developed by our group demonstrated their full applicability in E-Nose systems, opening a new and promising approach to the field. However, the operation of such sensor needs a background calibration phase which relies on the correct characterization and parameterization of the corresponding electrical sensor model.This paper proposes a model characterization methodology based on a set of frequency responses acquisitions of the sensor, under several humidity conditions. To obtain a flexible acquisition tool capable of acquiring accurate results, an analog front-end (AFE) circuit to interface with the interdigitated electrode (IDE) sensors is presented. Such AFE circuit is fully implemented using a programmable system-on-a-chip (PSoC), helping to reduce system size and cost. Lastly, a comparison between the electrical model and data acquired with the proposed system is presented.