Harmonics-transformer derating

D.W. Egolf, A. Flechsig
{"title":"Harmonics-transformer derating","authors":"D.W. Egolf, A. Flechsig","doi":"10.1109/ICPS.1994.303557","DOIUrl":null,"url":null,"abstract":"Power transformers supplying nonsinusoidal load current often need to be derated. The ANSI/IEEE C57.110-1986 standard provides a method by which derating may be performed. However, derating only provides an estimate of remaining transformer capacity, since subsequent load may significantly change the relative harmonic current values. The contribution of this paper is to provide a clear guide that can be used in applying the standard. This paper is not meant to replace the standard but to supplement it by providing correct examples and simplified equations.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Industrial and Commercial Power Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.1994.303557","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Power transformers supplying nonsinusoidal load current often need to be derated. The ANSI/IEEE C57.110-1986 standard provides a method by which derating may be performed. However, derating only provides an estimate of remaining transformer capacity, since subsequent load may significantly change the relative harmonic current values. The contribution of this paper is to provide a clear guide that can be used in applying the standard. This paper is not meant to replace the standard but to supplement it by providing correct examples and simplified equations.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Harmonics-transformer降额
提供非正弦负载电流的电力变压器经常需要降额。ANSI/IEEE C57.110-1986标准提供了一种可以执行降额的方法。然而,降额只能提供剩余变压器容量的估计,因为后续负载可能显著改变相对谐波电流值。本文的贡献在于为应用该标准提供了一个清晰的指南。本文不是要取代标准,而是通过提供正确的例子和简化的方程来补充标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Load modelling in commercial power systems using neural networks Characterization of power quality problems associated with large commercial customers served from large underground distribution network systems Fault analysis of multi-phase unbalanced non-radial power distribution systems Conversion of stand-by-generator facilities to combined heat and power units Electrical power system reliability case studies for water and wastewater treatment facilities
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1