Moisture Measurement of Transformer by Time Methods

M. Gutten, D. Korenčiak, M. Šebok, M. Kučera, Richard Janura
{"title":"Moisture Measurement of Transformer by Time Methods","authors":"M. Gutten, D. Korenčiak, M. Šebok, M. Kučera, Richard Janura","doi":"10.23919/MEASUREMENT47340.2019.8780032","DOIUrl":null,"url":null,"abstract":"The first part of the paper deals with the base information about base measuring methods of transformer insulating system. The second part of paper deals use of time methods - the method of return voltage measurement (RVM) and method of polarization depolarization current (PDC) for distribution transformer. These methods are used in the analysis of the insulating condition of power transformer with a system of oil-paper. In the other part, the paper presents experimental results of the moisture measurement for a real transformer 22/0.4 kV using time method RVM.","PeriodicalId":129350,"journal":{"name":"2019 12th International Conference on Measurement","volume":"227 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 12th International Conference on Measurement","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/MEASUREMENT47340.2019.8780032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The first part of the paper deals with the base information about base measuring methods of transformer insulating system. The second part of paper deals use of time methods - the method of return voltage measurement (RVM) and method of polarization depolarization current (PDC) for distribution transformer. These methods are used in the analysis of the insulating condition of power transformer with a system of oil-paper. In the other part, the paper presents experimental results of the moisture measurement for a real transformer 22/0.4 kV using time method RVM.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用时间法测量变压器水分
本文第一部分介绍了变压器绝缘系统基本测量方法的基本信息。论文的第二部分讨论了时间方法——配电变压器返回电压测量法(RVM)和极化去极化电流测量法(PDC)的应用。将这些方法应用于油纸系统电力变压器绝缘状况的分析。另一部分给出了用时间法RVM对实际22/0.4 kV变压器进行水分测量的实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Improvement of the Method for Measuring the Shock Tubes Velocity of Detonation by using a CNC Machined Base and Oscilloscopes Two-Dimensional Linear Comparative Calibration and Measurement Uncertainty Gradient Offset Calibration Used for B0Homogeneity The Effect of the Phenomenon of “Spectrum Leakage” on the Measurement of Power Quality Parameters Simple Seamless Multi-Range Current Measurement for Applications with a Large Dynamic Range
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1