Appropriate generation rate constraint (GRC) modeling method for reheat thermal units to obtain optimal load frequency controller (LFC)

J. Morsali, K. Zare, M. T. Hagh
{"title":"Appropriate generation rate constraint (GRC) modeling method for reheat thermal units to obtain optimal load frequency controller (LFC)","authors":"J. Morsali, K. Zare, M. T. Hagh","doi":"10.1109/CTPP.2014.7040611","DOIUrl":null,"url":null,"abstract":"This paper focuses on choosing a suitable dynamic model for simulation of generation rate constraint (GRC) for load frequency control (LFC) of an interconnected realistic reheat thermal-thermal power system. Two different dynamic models for simulation of the GRC are investigated in details which are named as open loop and closed loop GRC models. These models have been used widely in literature interchangeably without any further description to the reason of selected modeling method and its suitability. This paper makes an attempt to help in choosing more effective and appropriate GRC structure pertained to reheat thermal units based on dynamic simulations to obtain optimal LFC. Reheat thermal units are examined with different GRC models. Then, integral of time multiplied squared error (ITSE) performance index is minimized by an improved particle swarm optimization (IPSO) algorithm to optimize proportional-integral-derivative (PID) controller parameters. All simulations are performed in MATLAB/SIMULINK environment. The results of eigenvalue analysis, dynamic simulations, and robustness analysis reveal the appropriate GRC modeling method for thermal units to attain high-performance and optimal LFC design.","PeriodicalId":226320,"journal":{"name":"2014 5th Conference on Thermal Power Plants (CTPP)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 5th Conference on Thermal Power Plants (CTPP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CTPP.2014.7040611","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

This paper focuses on choosing a suitable dynamic model for simulation of generation rate constraint (GRC) for load frequency control (LFC) of an interconnected realistic reheat thermal-thermal power system. Two different dynamic models for simulation of the GRC are investigated in details which are named as open loop and closed loop GRC models. These models have been used widely in literature interchangeably without any further description to the reason of selected modeling method and its suitability. This paper makes an attempt to help in choosing more effective and appropriate GRC structure pertained to reheat thermal units based on dynamic simulations to obtain optimal LFC. Reheat thermal units are examined with different GRC models. Then, integral of time multiplied squared error (ITSE) performance index is minimized by an improved particle swarm optimization (IPSO) algorithm to optimize proportional-integral-derivative (PID) controller parameters. All simulations are performed in MATLAB/SIMULINK environment. The results of eigenvalue analysis, dynamic simulations, and robustness analysis reveal the appropriate GRC modeling method for thermal units to attain high-performance and optimal LFC design.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
再热机组最佳负荷频率控制器(LFC)的适当发电速率约束(GRC)建模方法
本文的重点是选择一个合适的动态模型来模拟一个互连现实再热热电系统的负荷频率控制(LFC)的发电速率约束(GRC)。详细研究了用于GRC仿真的两种不同的动力学模型:开环模型和闭环模型。这些模型在文献中被广泛地互换使用,而没有进一步说明所选择的建模方法的原因及其适用性。本文试图通过对热单元再热过程的动态模拟,帮助选择更有效、更合适的GRC结构,以获得最优LFC。用不同的GRC模型对再热单元进行了研究。然后,采用改进的粒子群优化算法(IPSO)最小化时间乘平方误差(ITSE)性能指标的积分,优化比例积分导数(PID)控制器参数;所有仿真均在MATLAB/SIMULINK环境下进行。特征值分析、动态仿真和鲁棒性分析的结果揭示了适合热单元的GRC建模方法,以实现高性能和最优的LFC设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Parallel operating of two energy storage battery systems using quasi Z-source inverter The impacts of Virtual Power Plants on multiple carrier energy networks Measurement of productivity changes by bootstrapping malmquist in combined cycle power plants Comparison of conventional and resonant boost converters for grid-connected solar systems Islanding detection of solar power plants by considering the dynamics of PV and MPPT
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1