Non-Destructive Liquid-Mixture Sensor Using Dual-Mushroom Resonator for Glucose Concentration Characterization

Sukanya Chudpooti, Patchadaporn Sangpet, Tanaporn Pechrkool, S. Chalermwisutkul, P. Akkaraekthalin
{"title":"Non-Destructive Liquid-Mixture Sensor Using Dual-Mushroom Resonator for Glucose Concentration Characterization","authors":"Sukanya Chudpooti, Patchadaporn Sangpet, Tanaporn Pechrkool, S. Chalermwisutkul, P. Akkaraekthalin","doi":"10.1109/RI2C51727.2021.9559803","DOIUrl":null,"url":null,"abstract":"This paper presents the non-destructive liquid-mixture sensor for glucose concentration characterization using the dual-mushroom resonator technique. The resonator is designed by using Jerusalem patch for reducing the size of a resonator, operating at 5.76 GHz with a total size of 10 × 30 mm2 (0.2λ0 × 0.2λ0). In the experimental measurement setup, the Teflon tube channel is placed on the top of the resonator patch. The liquid under test is filled into the Teflon tube using the syringe. The volume of the liquid under test is 100 µl. The liquid under test is a controlled temperature of 25 degrees Celcius. Six solutions, e.g., DI-water, 0.04 g/mL, 0.08 g/mL, 0.12 g/mL, 0.16 g/mL and 0.20 g/mL of D-glucose in DI-water, are selected for calibrating the proposed sensor. From the measurement results, the proposed sensor can classify the difference between D-glucose in the DI-water in each of 0.04 g/mL. The sensitivity of D-glucose solution in terms of reflection coefficient, S11, is 18.74 dB/g/mL. The extracted equation shows the regression coefficient better than 0.995 based on the 2nd order polynomial curve fitting technique. The non-destructive microwave liquid-mixture of D-glucose and DI-water offers advantage points, e.g., low-cost, long lifetime, no-additional chemical process, etc.","PeriodicalId":422981,"journal":{"name":"2021 Research, Invention, and Innovation Congress: Innovation Electricals and Electronics (RI2C)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Research, Invention, and Innovation Congress: Innovation Electricals and Electronics (RI2C)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RI2C51727.2021.9559803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents the non-destructive liquid-mixture sensor for glucose concentration characterization using the dual-mushroom resonator technique. The resonator is designed by using Jerusalem patch for reducing the size of a resonator, operating at 5.76 GHz with a total size of 10 × 30 mm2 (0.2λ0 × 0.2λ0). In the experimental measurement setup, the Teflon tube channel is placed on the top of the resonator patch. The liquid under test is filled into the Teflon tube using the syringe. The volume of the liquid under test is 100 µl. The liquid under test is a controlled temperature of 25 degrees Celcius. Six solutions, e.g., DI-water, 0.04 g/mL, 0.08 g/mL, 0.12 g/mL, 0.16 g/mL and 0.20 g/mL of D-glucose in DI-water, are selected for calibrating the proposed sensor. From the measurement results, the proposed sensor can classify the difference between D-glucose in the DI-water in each of 0.04 g/mL. The sensitivity of D-glucose solution in terms of reflection coefficient, S11, is 18.74 dB/g/mL. The extracted equation shows the regression coefficient better than 0.995 based on the 2nd order polynomial curve fitting technique. The non-destructive microwave liquid-mixture of D-glucose and DI-water offers advantage points, e.g., low-cost, long lifetime, no-additional chemical process, etc.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用双蘑菇谐振器的非破坏性液-混合液传感器用于葡萄糖浓度表征
本文介绍了一种利用双蘑菇谐振器技术进行葡萄糖浓度表征的无损液-混合液传感器。该谐振器采用减小谐振器尺寸的Jerusalem贴片设计,工作频率为5.76 GHz,总尺寸为10 × 30 mm2 (0.2λ0 × 0.2λ0)。在实验测量装置中,聚四氟乙烯管通道被放置在谐振器贴片的顶部。用注射器将待测液体填入特氟龙管。待测液体体积为100µl。被测液体的受控温度为25摄氏度。选用DI-water、0.04 g/mL、0.08 g/mL、0.12 g/mL、0.16 g/mL和0.20 g/mL的d -葡萄糖溶液对传感器进行标定。从测量结果来看,该传感器可以将DI-water中d -葡萄糖的差值分别分类为0.04 g/mL。d -葡萄糖溶液的反射系数S11的灵敏度为18.74 dB/g/mL。提取的方程表明,采用二阶多项式曲线拟合技术,回归系数优于0.995。d-葡萄糖和di -水的非破坏性微波混合液具有成本低、使用寿命长、不需要额外的化学处理等优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Mobile Warehouse Management and Transportation Planning System for Wheat Flour Design Guidelines of Passive Balancing Circuit for Li-Ion Battery for Bleeding Current Adjustment Using PWM Technique A Genetic Algorithm for Split Delivery Open Vehicle Routing Problem with Physical Workload Consideration Transfer of a scientific concept in the field of renewable energy with a creative group work Circularly Polarized Elliptical Patch Array Antennas for GPS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1