{"title":"A computerized random element stereogram generator: Design and experiments","authors":"M. Obaidat, J. Jagadeesh, L. Leguire","doi":"10.1109/ECBS.1988.5462","DOIUrl":null,"url":null,"abstract":"A microcomputer-based generator for random-element stereograms that generates different visual stimuli is described. The system allows any solid-shaped target to be programmed and varied in size or shape, movement and disparity. The generator creates elements on a color monitor with resolution of 750x512 pixels. Target size is dependent on overall monitor size, and programmable movement varies over a large range with three types of movement possible: sinusoidal, triangular and square wave. Both the disparity of the target and the background can be varied by seven picture elements. The entire system consists of a host computer, custom hardware for random stereogram generation, and software. The versatility of the system is demonstrated with eye movement and visual evoked response data.<<ETX>>","PeriodicalId":291071,"journal":{"name":"Proceedings of the Symposium on the Engineering of Computer-Based Medical","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Symposium on the Engineering of Computer-Based Medical","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECBS.1988.5462","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
A microcomputer-based generator for random-element stereograms that generates different visual stimuli is described. The system allows any solid-shaped target to be programmed and varied in size or shape, movement and disparity. The generator creates elements on a color monitor with resolution of 750x512 pixels. Target size is dependent on overall monitor size, and programmable movement varies over a large range with three types of movement possible: sinusoidal, triangular and square wave. Both the disparity of the target and the background can be varied by seven picture elements. The entire system consists of a host computer, custom hardware for random stereogram generation, and software. The versatility of the system is demonstrated with eye movement and visual evoked response data.<>