Wojciech Wojnowski, T. Majchrzak, J. Gębicki, T. Dymerski, J. Namieśnik
{"title":"Comparison of the measurement techniques employed for evaluation of ambient air odor quality","authors":"Wojciech Wojnowski, T. Majchrzak, J. Gębicki, T. Dymerski, J. Namieśnik","doi":"10.1117/12.2244678","DOIUrl":null,"url":null,"abstract":"The paper presents the results of investigation on ambient air odor quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field olfactometers were used to determine mean concentration of odorants, which amounted from 2.2 to 20.2 ou/m3 depending on the place of measurement. In case of the investigation with the electronic nose prototype a classification of the ambient air samples with respect to the place of sampling was performed utilizing the kNN (where k=3) algorithm supported with a cross-validation method. Correct classification of the ambient air samples was at the level of 47.9%. Performed investigation revealed that evaluation of the ambient air samples with respect to odor was possible using the electronic nose instrument.","PeriodicalId":101814,"journal":{"name":"Scientific Conference on Optical and Electronic Sensors","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scientific Conference on Optical and Electronic Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2244678","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The paper presents the results of investigation on ambient air odor quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field olfactometers were used to determine mean concentration of odorants, which amounted from 2.2 to 20.2 ou/m3 depending on the place of measurement. In case of the investigation with the electronic nose prototype a classification of the ambient air samples with respect to the place of sampling was performed utilizing the kNN (where k=3) algorithm supported with a cross-validation method. Correct classification of the ambient air samples was at the level of 47.9%. Performed investigation revealed that evaluation of the ambient air samples with respect to odor was possible using the electronic nose instrument.