Analysis of the insulated power-grid transient behavior after faulted phase tripping

N. Berbic, A. Nuhanovic, V. Madžarević
{"title":"Analysis of the insulated power-grid transient behavior after faulted phase tripping","authors":"N. Berbic, A. Nuhanovic, V. Madžarević","doi":"10.1109/MELCON.2004.1348219","DOIUrl":null,"url":null,"abstract":"The common cases of a nonselective operation of the phase to ground fault protection in the insulated power grids, which utilize inductive sensors for a voltage unbalance indication, are explained by ferroresonant processes in voltage transformers of healthy drains. This paper deals with phase to ground faults simulations in a known grid, that provide information about possible nonselective phase to ground faults protection operation.","PeriodicalId":164818,"journal":{"name":"Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MELCON.2004.1348219","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The common cases of a nonselective operation of the phase to ground fault protection in the insulated power grids, which utilize inductive sensors for a voltage unbalance indication, are explained by ferroresonant processes in voltage transformers of healthy drains. This paper deals with phase to ground faults simulations in a known grid, that provide information about possible nonselective phase to ground faults protection operation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
故障脱相后绝缘电网暂态特性分析
利用电感传感器进行电压不平衡指示的绝缘电网中相接地故障保护的非选择性操作的常见情况,用健康漏极电压互感器中的铁谐振过程来解释。本文对已知电网的相地故障进行仿真,为可能出现的非选择相地故障保护操作提供信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Virtual restoration of fragmented glass plate photographs Multirate decorrelating detector for UMTS Experimental comparison of substrate structures for inductors and transformers Illegal connection location on main power cable Formal verification of ad-hoc routing protocols using SPIN model checker
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1