{"title":"A luminance control method for OLED burn-in prevention using user information","authors":"Hong-Kyu Shin, Hea-Bin Yang, S. Baek, Sung-Jea Ko","doi":"10.1109/ICCE53296.2022.9730535","DOIUrl":null,"url":null,"abstract":"In this paper, we propose a novel luminance control method utilizing user information (UI) to prevent burn-in in organic light emitting diode (OLED) displays. To control the luminance on a burn-in potential region (BPR), we first calculate the visual angle of each pixel on display utilizing UI and design a visual acuity model based on the cortical magnification theory. Next, we generate a UI-based saliency map by combining the visual acuity model and an image saliency map. Finally, the luminance of the BPR is adjusted based on the UI-based saliency map and the local contrast of the BPR. Experimental results show that the proposed method not only controls the luminance of the BPR to a degree of which users barely notice the change but also greatly extends the lifetime of the OLED.","PeriodicalId":350644,"journal":{"name":"2022 IEEE International Conference on Consumer Electronics (ICCE)","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on Consumer Electronics (ICCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCE53296.2022.9730535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this paper, we propose a novel luminance control method utilizing user information (UI) to prevent burn-in in organic light emitting diode (OLED) displays. To control the luminance on a burn-in potential region (BPR), we first calculate the visual angle of each pixel on display utilizing UI and design a visual acuity model based on the cortical magnification theory. Next, we generate a UI-based saliency map by combining the visual acuity model and an image saliency map. Finally, the luminance of the BPR is adjusted based on the UI-based saliency map and the local contrast of the BPR. Experimental results show that the proposed method not only controls the luminance of the BPR to a degree of which users barely notice the change but also greatly extends the lifetime of the OLED.