New multi-sector reconstruction for cardiac CT

T. Pan, Yun Shen
{"title":"New multi-sector reconstruction for cardiac CT","authors":"T. Pan, Yun Shen","doi":"10.1109/NSSMIC.2000.950077","DOIUrl":null,"url":null,"abstract":"Summary form only given. We have developed a new multi-sector reconstruction for multi-slice CT with EKG-gating to improve the temporal resolution of cardiac CT imaging. The reconstruction utilizes the sub-second gantry speed and large coverage of the multi-slice CT and EKG-gating to image the heart with thin-slice collimation in a single breath hold. The scan data are taken at pitch of about 1, and gantry speed of 0.8 or 1.0 sec chosen based on the patient heart rate. Utilizing the periodicity cardiac motion, the multi-sector reconstruction improves temporal resolution of reconstructed images up to 4 times. When the gantry speed is faster or slower than the cardiac cycle, a phase difference is created and the phase difference enables the data of current cycle to be combined with the data of the same cardiac phase in the next cardiac cycle for the same temporal resolution. If we combine two to four sectors of the data from 2 to 4 cardiac cycles to make up the data for reconstruction, the temporal resolution will be improved by 2 to 4 times. Phantom and patient studies are included to demonstrate the improvement of temporal resolution by the new multi-sector reconstruction.","PeriodicalId":445100,"journal":{"name":"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2000.950077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Summary form only given. We have developed a new multi-sector reconstruction for multi-slice CT with EKG-gating to improve the temporal resolution of cardiac CT imaging. The reconstruction utilizes the sub-second gantry speed and large coverage of the multi-slice CT and EKG-gating to image the heart with thin-slice collimation in a single breath hold. The scan data are taken at pitch of about 1, and gantry speed of 0.8 or 1.0 sec chosen based on the patient heart rate. Utilizing the periodicity cardiac motion, the multi-sector reconstruction improves temporal resolution of reconstructed images up to 4 times. When the gantry speed is faster or slower than the cardiac cycle, a phase difference is created and the phase difference enables the data of current cycle to be combined with the data of the same cardiac phase in the next cardiac cycle for the same temporal resolution. If we combine two to four sectors of the data from 2 to 4 cardiac cycles to make up the data for reconstruction, the temporal resolution will be improved by 2 to 4 times. Phantom and patient studies are included to demonstrate the improvement of temporal resolution by the new multi-sector reconstruction.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型心脏CT多扇形重建
只提供摘要形式。为了提高心脏CT成像的时间分辨率,我们开发了一种新的多层CT多扇区重构方法。重建利用亚秒龙门速度和多层CT和心电图门控的大覆盖范围,在单次屏气中对心脏进行薄层准直成像。扫描数据的间距约为1,根据患者的心率选择0.8或1.0秒的门框速度。利用心脏运动的周期性,多扇区重建将重建图像的时间分辨率提高了4倍。当龙门速度快于或慢于心动周期时,产生相位差,相位差使当前心动周期的数据与下一个心动周期的相同心动阶段的数据相结合,获得相同的时间分辨率。如果将2 ~ 4个心动周期数据的2 ~ 4个扇区组合起来进行重构,时间分辨率将提高2 ~ 4倍。包括幻影和患者研究,以证明新的多扇区重建改善了时间分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of a low-cost extruded scintillator with co-extruded reflector for the MINOS experiment The GREAT triggerless total data readout method Spatially dependent response of thick and large area PIN diode developed for ASTRO-E hard X-ray detector Implementation and evaluation of a 3D OSEM and median root prior (3D OSEM-MRP) reconstruction algorithm Comparison of the SSRB, MSRB, and FORE methods with the 3DRP algorithm using data from a high resolution PET scanner
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1