Yong Yang, Y. Ruan, Yan-Yan Tan, Bing-ying Ye, Yi-ming Zhang
{"title":"Research on multiple armature-winding hybrid-excitation generator in direct-driven wind power generation system","authors":"Yong Yang, Y. Ruan, Yan-Yan Tan, Bing-ying Ye, Yi-ming Zhang","doi":"10.1109/IPEMC.2009.5157466","DOIUrl":null,"url":null,"abstract":"The paper deals with the control of the multiple armature-winding hybrid-excitation generator(MAHEG) which is used for wind generation. Thus, a rectifier is required between the generator and DC bus. A diode rectifier is preferred here due to its great reliability and because it is also a low-cost solution. Discontinuous PWM have gained special attention for their reduced switching losses. According to the characteristic of grid-connected inverters, the mode of DPWM1 is adopted. Grid voltage orientation vector control strategy is adopted for both inverter, so the active and the reactive power can be independently controlled by d axis current and q axis current. Simulated and experimental results verify the feasibility and correctness for the control strategy.","PeriodicalId":375971,"journal":{"name":"2009 IEEE 6th International Power Electronics and Motion Control Conference","volume":"90 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE 6th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2009.5157466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The paper deals with the control of the multiple armature-winding hybrid-excitation generator(MAHEG) which is used for wind generation. Thus, a rectifier is required between the generator and DC bus. A diode rectifier is preferred here due to its great reliability and because it is also a low-cost solution. Discontinuous PWM have gained special attention for their reduced switching losses. According to the characteristic of grid-connected inverters, the mode of DPWM1 is adopted. Grid voltage orientation vector control strategy is adopted for both inverter, so the active and the reactive power can be independently controlled by d axis current and q axis current. Simulated and experimental results verify the feasibility and correctness for the control strategy.