{"title":"Relation of defibrillatory potential minima to post-defibrillatory activation","authors":"F. Witkowski, P. Penkoske","doi":"10.1109/IEMBS.1988.94483","DOIUrl":null,"url":null,"abstract":"Management of patients with malignant arrhythmias occurring outside the hospital and the development of clinically applicable systems for internal defibrillation have stimulated interest in the factors influencing cardiac defibrillation. Using a directly coupled (DC) electrode and amplification scheme, the authors have developed a system capable of simultaneous three-dimensional mapping of both the high energy shock field created in the heart by defibrillation electrodes in addition to the mapping of the immediate postshock myocardial activation sequence. Experiments performed in vivo in anesthetized open-chest dogs revealed that successful defibrillation required 100% of the site examined to be depolarized, with the first post defibrillation beat originating in the area of minimum defibrillatory potential.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1988.94483","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Management of patients with malignant arrhythmias occurring outside the hospital and the development of clinically applicable systems for internal defibrillation have stimulated interest in the factors influencing cardiac defibrillation. Using a directly coupled (DC) electrode and amplification scheme, the authors have developed a system capable of simultaneous three-dimensional mapping of both the high energy shock field created in the heart by defibrillation electrodes in addition to the mapping of the immediate postshock myocardial activation sequence. Experiments performed in vivo in anesthetized open-chest dogs revealed that successful defibrillation required 100% of the site examined to be depolarized, with the first post defibrillation beat originating in the area of minimum defibrillatory potential.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
除颤电位最小值与除颤后激活的关系
院外恶性心律失常患者的管理和临床适用的内部除颤系统的发展激发了对心脏除颤影响因素的兴趣。使用直接耦合(DC)电极和放大方案,作者开发了一种系统,该系统能够同时对除颤电极在心脏中产生的高能量冲击场进行三维映射,以及对休克后立即心肌激活序列进行映射。在麻醉开胸犬体内进行的实验显示,成功的除颤需要100%的检查部位去极化,除颤后的第一次心跳起源于最低除颤电位的区域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prognostic value of morphometry in papillary thyroid carcinoma An expert system approach to cystic fibrosis patient management Design and development of an electromagnetic cervical range of motion system EMG pattern classification of normal and anterior cruciate ligament injured subjects On-line system for automated auditory evoked response threshold determination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1