CONTROL TEST OF A WEARABLE ELBOW ORTHOSIS WITH BI-MUSCULAR PNEUMATIC SERVO-DRIVE BASED ON BRAIN-COMPUTER INTERFACE

R. Dindorf, P. Woś
{"title":"CONTROL TEST OF A WEARABLE ELBOW ORTHOSIS WITH BI-MUSCULAR PNEUMATIC SERVO-DRIVE BASED ON BRAIN-COMPUTER INTERFACE","authors":"R. Dindorf, P. Woś","doi":"10.21495/71-0-93","DOIUrl":null,"url":null,"abstract":": The paper presents a control tests of a wearable orthosis of elbow joint with a bi-muscular pneumatic servo-drive. Brain-computer interface (BCI) based control is a complex task, because it must contain a device for recording bioelectric signals (BESs) and translate them into control signals (CS) of the elbow orthosis. The authors analysed the impact of the induced brain activity and the muscular tension within the head of the participant on the BESs which can be used to control the pneumatic servo drive of the elbow joint orthosis. For controlling the elbow joint orthosis, a distributed control system (DCS) was developed that contains two control layers: a master layer connected to the BCI device and a direct layer contained in a wireless manner with the controller of the pneumatic servo-drive (PSD). In the programming of the PSD controller, a kinematic-dynamic model of the elbow joint orthosis, patterned after the biological model of human biceps-triceps, was used. A biomimetic dynamic model of the pneumatic muscle actuator (PMA) was used, in which the contraction force results from the adopted exponential static model of the pneumatic muscle (PM). Use of direct visual feedback (DVF) makes it possible for the participant to focus on the movement of the orthosis taking into account the motoric functions of the elbow.","PeriodicalId":197313,"journal":{"name":"Engineering Mechanics 2019","volume":"157 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering Mechanics 2019","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21495/71-0-93","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

: The paper presents a control tests of a wearable orthosis of elbow joint with a bi-muscular pneumatic servo-drive. Brain-computer interface (BCI) based control is a complex task, because it must contain a device for recording bioelectric signals (BESs) and translate them into control signals (CS) of the elbow orthosis. The authors analysed the impact of the induced brain activity and the muscular tension within the head of the participant on the BESs which can be used to control the pneumatic servo drive of the elbow joint orthosis. For controlling the elbow joint orthosis, a distributed control system (DCS) was developed that contains two control layers: a master layer connected to the BCI device and a direct layer contained in a wireless manner with the controller of the pneumatic servo-drive (PSD). In the programming of the PSD controller, a kinematic-dynamic model of the elbow joint orthosis, patterned after the biological model of human biceps-triceps, was used. A biomimetic dynamic model of the pneumatic muscle actuator (PMA) was used, in which the contraction force results from the adopted exponential static model of the pneumatic muscle (PM). Use of direct visual feedback (DVF) makes it possible for the participant to focus on the movement of the orthosis taking into account the motoric functions of the elbow.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于脑机接口的双肌肉气动伺服可穿戴肘矫形器控制试验
本文介绍了一种双肌肉气动伺服驱动可穿戴式肘关节矫形器的控制试验。基于脑机接口(BCI)的控制是一项复杂的任务,因为它必须包含一个记录生物电信号(BESs)并将其转化为肘部矫形器的控制信号(CS)的装置。作者分析了受试者脑活动诱导和头部肌肉张力对BESs的影响,BESs可用于控制肘关节矫形器的气动伺服驱动。为了控制肘关节矫形器,开发了一种分布式控制系统(DCS),该系统包含两个控制层:主层连接到BCI设备,直接层以无线方式包含与气动伺服驱动(PSD)控制器。在PSD控制器的编程中,使用了一个模仿人类二头肌-三头肌生物学模型的肘关节矫形器的运动学-动力学模型。建立了气动肌肉执行器(PMA)的仿生动力学模型,其中收缩力来源于所采用的气动肌肉(PM)的指数静态模型。使用直接视觉反馈(DVF)使参与者能够专注于矫形器的运动,同时考虑到肘部的运动功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
DESIGN RESISTANCE OF STAINLESS-STEEL FILLET WELDS STAND FOR TESTING SENSITIVITY IMPACT OF RADIO PROXIMITY SENSORS NUMERICAL ANALYSIS OF THE INFLUENCE OF INITIAL POSITION OF A PISTON ON FLUID EXCHANGE PROCESS IN A HYDRAULIC CYLINDER RAPID RESEARCH WITH COMPUTER ALGEBRA SYSTEMS EFFECT OF PIPE INCLINATION ON LOCAL CONCENTRATION AND FLOW BEHAVIOUR OF SETTLING SLURRY
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1