Performance of distance based and path loss based weighted centroid localization algorithms for video capsule endoscope

Umma Hany, L. Akter
{"title":"Performance of distance based and path loss based weighted centroid localization algorithms for video capsule endoscope","authors":"Umma Hany, L. Akter","doi":"10.1109/ICSIPA.2017.8120591","DOIUrl":null,"url":null,"abstract":"In this paper, we propose distance and path loss based weighted centroid localization (WCL) algorithms for video capsule endoscope (VCE) using the received signal strength indicator (RSSI). We evaluate the performance of both algorithms considering real channel characteristics of human body. One of the major challenge in RSSI based VCE localization is the shadow fading and multi-path propagation effects of non-homogeneous medium of human body for which the measured RSSI is highly random resulting in high localization error. Again, due to the complex environment of experiment, accurate estimation of the channel parameters is quite difficult. We evaluate the performance of both algorithms in presence of randomness in path loss and estimation errors in channel parameters. To address the randomness issue, we estimate the smoothed path loss using moving averaging filter. Then, we introduce 10–50% errors in channel parameters to analyze the performance of both algorithms. We develop a simulation tool using MATLAB to visualize the results and to compare the performance. We observe significant improvement in performance by applying moving averaging method of smoothed path loss estimation using both algorithms. We also observe that the accuracy of distance based WCL decreases significantly in presence of errors in channel parameters. Whereas path loss based WCL is robust to the errors in channel parameters as it estimates the positions by using the estimated path loss directly without prior precise knowledge of channel parameters.","PeriodicalId":268112,"journal":{"name":"2017 IEEE International Conference on Signal and Image Processing Applications (ICSIPA)","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE International Conference on Signal and Image Processing Applications (ICSIPA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSIPA.2017.8120591","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this paper, we propose distance and path loss based weighted centroid localization (WCL) algorithms for video capsule endoscope (VCE) using the received signal strength indicator (RSSI). We evaluate the performance of both algorithms considering real channel characteristics of human body. One of the major challenge in RSSI based VCE localization is the shadow fading and multi-path propagation effects of non-homogeneous medium of human body for which the measured RSSI is highly random resulting in high localization error. Again, due to the complex environment of experiment, accurate estimation of the channel parameters is quite difficult. We evaluate the performance of both algorithms in presence of randomness in path loss and estimation errors in channel parameters. To address the randomness issue, we estimate the smoothed path loss using moving averaging filter. Then, we introduce 10–50% errors in channel parameters to analyze the performance of both algorithms. We develop a simulation tool using MATLAB to visualize the results and to compare the performance. We observe significant improvement in performance by applying moving averaging method of smoothed path loss estimation using both algorithms. We also observe that the accuracy of distance based WCL decreases significantly in presence of errors in channel parameters. Whereas path loss based WCL is robust to the errors in channel parameters as it estimates the positions by using the estimated path loss directly without prior precise knowledge of channel parameters.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于距离和路径损失的视频胶囊内窥镜加权质心定位算法的性能
在本文中,我们提出了基于距离和路径损失的加权质心定位(WCL)算法,用于视频胶囊内窥镜(VCE)的接收信号强度指示器(RSSI)。考虑到人体的真实信道特性,对两种算法的性能进行了评价。基于RSSI的VCE定位面临的主要挑战之一是人体非均匀介质的阴影衰落和多径传播效应,测量的RSSI高度随机,导致定位误差很大。再次,由于实验环境的复杂,通道参数的准确估计是相当困难的。我们评估了两种算法在存在路径损失随机性和信道参数估计误差的情况下的性能。为了解决随机问题,我们使用移动平均滤波器估计平滑路径损失。然后,我们引入10-50%的信道参数误差来分析两种算法的性能。我们开发了一个仿真工具,使用MATLAB将结果可视化并对性能进行比较。我们观察到在两种算法中应用平滑路径损失估计的移动平均方法显著提高了性能。我们还观察到,在信道参数存在误差的情况下,基于距离的WCL的精度显著降低。然而,基于路径损耗的WCL对信道参数误差具有鲁棒性,因为它直接使用估计的路径损耗来估计位置,而无需事先精确了解信道参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Enhanced forensic speaker verification using multi-run ICA in the presence of environmental noise and reverberation conditions A real-time multi-class multi-object tracker using YOLOv2 Hybrid neural network and regression tree ensemble pruned by simulated annealing for virtual flow metering application Hybrid DWT and MFCC feature warping for noisy forensic speaker verification in room reverberation A deep architecture for face recognition based on multiple feature extraction techniques
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1