Indirectly-coupled optical resonators for anti-parity-time-symmetric gyroscopes

Martino De Carlo, F. De Leonardis, F. Dell’Olio, Pietro Peliti, Fabrizio Berton, Mario Lucchesini, V. Passaro
{"title":"Indirectly-coupled optical resonators for anti-parity-time-symmetric gyroscopes","authors":"Martino De Carlo, F. De Leonardis, F. Dell’Olio, Pietro Peliti, Fabrizio Berton, Mario Lucchesini, V. Passaro","doi":"10.1109/INERTIAL53425.2022.9787722","DOIUrl":null,"url":null,"abstract":"Optical gyroscopes, which exploit the Sagnac effect, are one of the preferred choices for high-resolution sensing of angular velocity. However, their miniaturization and integration for high-resolution sensing is still a challenge in optoelectronics research. In fact, in interferometric fiber-optic gyroscopes (IFOGs) the sensitivity is proportional to the area enclosed by the fiber-optic sensing coil. Whereas, in resonant fiber-optic gyroscopes (RFOGs) and resonant micro-optical gyroscopes (RMOGs) the sensitivity is proportional to the ratio between the area enclosed by the cavity and the perimeter of the cavity. Non-Hermitian optical architectures (especially with parity-time-symmetric Hamiltonians) have been recently proposed in literature to solve this scaling problem. In this work, an anti-parity-time-symmetric gyroscope has been designed with two resonant cavities, indirectly coupled via an auxiliary bus. At the operating condition of the so-called \"exceptional point\", it is possible to demonstrate that the sensitivity of the gyroscope is independent of the dimensions of the device. Finally, it will be shown that the anti-parity-time-symmetric architectures represent a better choice for angular velocity sensing than the parity-time symmetric version. An enhancement of the sensitivity of several orders of magnitude with respect to standard Sagnac-based gyros with the same footprint is expected.","PeriodicalId":435781,"journal":{"name":"2022 IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INERTIAL53425.2022.9787722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Optical gyroscopes, which exploit the Sagnac effect, are one of the preferred choices for high-resolution sensing of angular velocity. However, their miniaturization and integration for high-resolution sensing is still a challenge in optoelectronics research. In fact, in interferometric fiber-optic gyroscopes (IFOGs) the sensitivity is proportional to the area enclosed by the fiber-optic sensing coil. Whereas, in resonant fiber-optic gyroscopes (RFOGs) and resonant micro-optical gyroscopes (RMOGs) the sensitivity is proportional to the ratio between the area enclosed by the cavity and the perimeter of the cavity. Non-Hermitian optical architectures (especially with parity-time-symmetric Hamiltonians) have been recently proposed in literature to solve this scaling problem. In this work, an anti-parity-time-symmetric gyroscope has been designed with two resonant cavities, indirectly coupled via an auxiliary bus. At the operating condition of the so-called "exceptional point", it is possible to demonstrate that the sensitivity of the gyroscope is independent of the dimensions of the device. Finally, it will be shown that the anti-parity-time-symmetric architectures represent a better choice for angular velocity sensing than the parity-time symmetric version. An enhancement of the sensitivity of several orders of magnitude with respect to standard Sagnac-based gyros with the same footprint is expected.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
反宇称时间对称陀螺仪的间接耦合光学谐振器
利用Sagnac效应的光学陀螺仪是高分辨率角速度传感的首选之一。然而,它们的小型化和高分辨率传感的集成化仍然是光电子学研究的一个挑战。实际上,在干涉式光纤陀螺仪(IFOGs)中,灵敏度与光纤传感线圈所包围的面积成正比。而在谐振式光纤陀螺仪和谐振式微光陀螺仪中,灵敏度与腔所包围的面积与腔周长之比成正比。非厄米光学体系结构(特别是具有奇偶时间对称的哈密顿量)最近在文献中被提出来解决这个缩放问题。在这项工作中,设计了一个具有两个谐振腔的反宇称时间对称陀螺仪,通过辅助总线间接耦合。在所谓的“异常点”的操作条件下,有可能证明陀螺仪的灵敏度与设备的尺寸无关。最后,将证明反奇偶时间对称架构比奇偶时间对称版本代表了更好的角速度感知选择。与具有相同足迹的基于sagnac的标准陀螺仪相比,预期灵敏度将提高几个数量级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Glass Molding for Microstructures Miniaturized Navigation Grade Quartz Vba Accelerometer For Space Applications 0.25 deg/h Closed-Loop Bulk Acoustic Wave Gyroscope Temperature Drift Self-calibration for Honeycomb-like Disk Resonator Gyroscope Wobble Estimation of a Turntable axis by using an Inertial Measurement Unit
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1