{"title":"Flower Pollination Algorithm Based Sizing and Placement of DG and D-STATCOM Simultaneously in Radial Distribution Systems","authors":"Vittal Bhat, Manjappa","doi":"10.1109/NPSC.2018.8771803","DOIUrl":null,"url":null,"abstract":"In this paper, various distribution systems are analyzed for optimal placement and sizing of Distributed Generation (DG) & Distribution Static Compensator (D-STATCOM) incorporated by Flower Pollination Algorithm (FPA). The Loss Sensitivity Factor (LSF) is considered as a critical aspect in determining the selection of candidate buses for installation of DG and D-STATCOM. In order to demonstrate the effectiveness of FPA it is implemented on 15, 33 and 69 bus radial distribution systems (RDS) to derive the locations and sizing of DG and D-STATCOM based on the selected candidate buses. Comparison of the results obtained by the FPA with the base case infers that the power losses are reduced with increased net saving and improved voltage profiles for the tested distribution systems.","PeriodicalId":185930,"journal":{"name":"2018 20th National Power Systems Conference (NPSC)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 20th National Power Systems Conference (NPSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NPSC.2018.8771803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
In this paper, various distribution systems are analyzed for optimal placement and sizing of Distributed Generation (DG) & Distribution Static Compensator (D-STATCOM) incorporated by Flower Pollination Algorithm (FPA). The Loss Sensitivity Factor (LSF) is considered as a critical aspect in determining the selection of candidate buses for installation of DG and D-STATCOM. In order to demonstrate the effectiveness of FPA it is implemented on 15, 33 and 69 bus radial distribution systems (RDS) to derive the locations and sizing of DG and D-STATCOM based on the selected candidate buses. Comparison of the results obtained by the FPA with the base case infers that the power losses are reduced with increased net saving and improved voltage profiles for the tested distribution systems.