A novel control scheme for PMBLDC drives

U. Kalla, K. Rathore
{"title":"A novel control scheme for PMBLDC drives","authors":"U. Kalla, K. Rathore","doi":"10.1109/POWERI.2016.8077466","DOIUrl":null,"url":null,"abstract":"This paper aimed at a power factor correction (PFC) based novel speed control for standalone generator fed PMBLDC drives. The scheme is highly suitable for obtaining unity power factor operation in standalone generator fed PMBLDC drive, since the reference current signal in this control scheme is estimated using a frequency adaptive unit template block. The system frequency in any standalone generating system like diesel generator (DG) sets and small hydro power generation systems, is depends on loading condition of the generator. Therefore the system frequency of such system fluctuates under varying load conditions. The proposed frequency adaptive unit template based scheme is essentially required to achieve the power factor correction operation in standalone generation driven PMBLDC drives. Therefore a new PFC scheme is proposed for PMBLDC drive fed by a single phase standalone power generating system.","PeriodicalId":332286,"journal":{"name":"2016 IEEE 7th Power India International Conference (PIICON)","volume":"81 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 7th Power India International Conference (PIICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERI.2016.8077466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper aimed at a power factor correction (PFC) based novel speed control for standalone generator fed PMBLDC drives. The scheme is highly suitable for obtaining unity power factor operation in standalone generator fed PMBLDC drive, since the reference current signal in this control scheme is estimated using a frequency adaptive unit template block. The system frequency in any standalone generating system like diesel generator (DG) sets and small hydro power generation systems, is depends on loading condition of the generator. Therefore the system frequency of such system fluctuates under varying load conditions. The proposed frequency adaptive unit template based scheme is essentially required to achieve the power factor correction operation in standalone generation driven PMBLDC drives. Therefore a new PFC scheme is proposed for PMBLDC drive fed by a single phase standalone power generating system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种新的永磁无刷直流驱动器控制方案
本文研究了一种基于功率因数校正(PFC)的独立发电机供电PMBLDC驱动器的新型速度控制方法。由于该控制方案采用频率自适应单元模板块估计参考电流信号,因此该方案非常适合于在独立发电机供电的PMBLDC驱动器中获得单位功率因数运行。在任何独立发电系统中,如柴油发电机组和小型水力发电系统,其系统频率取决于发电机的负载状况。因此,该系统的系统频率在不同的负载条件下波动。提出的基于频率自适应单元模板的方案是实现独立发电驱动PMBLDC驱动器功率因数校正操作所必需的。为此,提出了一种新的单相独立发电系统驱动PMBLDC的PFC方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Detection of power quality disturbances in the utility grid with solar energy using S-transform Full bridge level doubling network assisted multilevel DC link inverter Distribution system expansion planning incorporating distributed generation A solar PV system controlled by least sum of exponentials algorithm Photo-voltaic system for refrigeration plants in isolated areas
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1