A robust six-to-four port reduction technique for the calibration of six-port microwave network analysers

A. Wright, S. Judah
{"title":"A robust six-to-four port reduction technique for the calibration of six-port microwave network analysers","authors":"A. Wright, S. Judah","doi":"10.1109/IMTC.1990.65977","DOIUrl":null,"url":null,"abstract":"The authors introduce a simple method by which the robust calibration technique developed by S.K. Judah (1985) may be unified with the thru-reflect-line technique, yielding initial estimates of the six-port instrumental parameters that are insensitive to noise and random errors. This calibration technique has been employed in a single six-port reflectometer operating at 2 GHz. Experimental experience has shown the technique to be robust; problems encountered using the method recommended by G.F. Engen (1979) have not arisen. Investigation by computer simulation has also shown the technique to be reliable. This methodology requires a substantial increase in software effort owing to the effective operational requirement of two full calibration techniques.<<ETX>>","PeriodicalId":404761,"journal":{"name":"7th IEEE Conference on Instrumentation and Measurement Technology","volume":"147 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"7th IEEE Conference on Instrumentation and Measurement Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1990.65977","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The authors introduce a simple method by which the robust calibration technique developed by S.K. Judah (1985) may be unified with the thru-reflect-line technique, yielding initial estimates of the six-port instrumental parameters that are insensitive to noise and random errors. This calibration technique has been employed in a single six-port reflectometer operating at 2 GHz. Experimental experience has shown the technique to be robust; problems encountered using the method recommended by G.F. Engen (1979) have not arisen. Investigation by computer simulation has also shown the technique to be reliable. This methodology requires a substantial increase in software effort owing to the effective operational requirement of two full calibration techniques.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于校准六端口微波网络分析仪的鲁棒六到四端口缩减技术
作者介绍了一种简单的方法,通过这种方法,S.K. Judah(1985)开发的鲁棒校准技术可以与透反射线技术统一起来,产生对噪声和随机误差不敏感的六端口仪器参数的初步估计。该校准技术已应用于一个工作频率为2ghz的单六端口反射计。实验经验表明,该方法具有较强的鲁棒性;使用G.F. Engen(1979)推荐的方法所遇到的问题没有出现。计算机仿真研究也证明了该方法的可靠性。由于两种完整校准技术的有效操作要求,该方法需要大量增加软件工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Theoretical aspects of calibration procedures in network analyzers for nonlinear one port devices The digital measurement of low values of angular velocity and acceleration MMIC related metrology at the National Institute of Standards and Technology Parameter estimation in strongly nonlinear circuits Second order discriminant function for amplitude comparison monopulse
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1