{"title":"Unbalance in Parallel Interconnector Circuits","authors":"J. Evans","doi":"10.1109/UPEC.2006.367769","DOIUrl":null,"url":null,"abstract":"This paper investigates current unbalance in parallel cable interconnector circuits. Several instances have been observed where an MV switchboard loses supply during a motor starting transient. In each instance the affected switchboard was supplied via two interconnector cables operating in parallel. During motor starting, the transient current was not shared equally between the interconnector red, blue and yellow phases. The protection on each interconnector interpreted the unbalance in the phases as an earth fault and initiated a trip. To establish that the unbalance is not due to load or current transformer spill current, steady-state and transient measurements have been made. Steady-state and transient PSCAD simulations have been performed to investigate possible causes of the unequal current sharing between parallel interconnectors.","PeriodicalId":184186,"journal":{"name":"Proceedings of the 41st International Universities Power Engineering Conference","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2006.367769","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper investigates current unbalance in parallel cable interconnector circuits. Several instances have been observed where an MV switchboard loses supply during a motor starting transient. In each instance the affected switchboard was supplied via two interconnector cables operating in parallel. During motor starting, the transient current was not shared equally between the interconnector red, blue and yellow phases. The protection on each interconnector interpreted the unbalance in the phases as an earth fault and initiated a trip. To establish that the unbalance is not due to load or current transformer spill current, steady-state and transient measurements have been made. Steady-state and transient PSCAD simulations have been performed to investigate possible causes of the unequal current sharing between parallel interconnectors.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
并联互连电路中的不平衡
本文研究了并联电缆互连电路中的电流不平衡问题。已经观察到几个实例,其中中压开关板在电机启动瞬态期间失去电源。在每种情况下,受影响的配电板都是通过两条并联的互连电缆供电的。在电动机起动过程中,瞬态电流在互连的红、蓝、黄三相之间不均匀分布。每个互连器上的保护将相中的不平衡解释为接地故障并启动跳闸。为了确定不平衡不是由于负载或电流互感器溢出电流造成的,进行了稳态和瞬态测量。通过稳态和瞬态PSCAD仿真,研究了并联互连器之间电流分担不均匀的可能原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transient Short-Circuit Behaviour of Distributed Energy Sources and Their Influence on Protection Coordination Using Active Power Filter Based on New Control Strategy to Compensate Power Quality Assessment of DSM Potential in the Governmental Sector in Egypt and its Effect on the National Power System Development A New Method for the Price Determination of the Reactive Power Supply Grid Integration of Wind Farms Using SVC and STATCOM
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1