{"title":"CCVT impact on the TD21 function security","authors":"E. A. Custódio, F. Lopes, J. Ribeiro","doi":"10.1109/WCNPS.2017.8253083","DOIUrl":null,"url":null,"abstract":"The use of high-speed protection relays allows an increasing of the power transmitted in transmission lines that are already in operation. The function analyzed in this paper uses instantaneous values of the incremental voltages and currents for the calculation of the fault position in relation to a protected zone, presenting average operation times smaller than those obtained through traditional phasor-based functions. In this way, the impact of the coupling capacitive voltage transformers (CCVT) on the security of the time-domain distance protection function TD21 is analyzed, comparing its performance when primary and secondary voltages signals are taken into account.","PeriodicalId":293027,"journal":{"name":"2017 Workshop on Communication Networks and Power Systems (WCNPS)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Workshop on Communication Networks and Power Systems (WCNPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WCNPS.2017.8253083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The use of high-speed protection relays allows an increasing of the power transmitted in transmission lines that are already in operation. The function analyzed in this paper uses instantaneous values of the incremental voltages and currents for the calculation of the fault position in relation to a protected zone, presenting average operation times smaller than those obtained through traditional phasor-based functions. In this way, the impact of the coupling capacitive voltage transformers (CCVT) on the security of the time-domain distance protection function TD21 is analyzed, comparing its performance when primary and secondary voltages signals are taken into account.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CCVT对TD21功能安全性的影响
使用高速保护继电器可以增加已经在运行的输电线路中传输的功率。本文分析的函数利用电压和电流增量的瞬时值来计算相对于保护区域的故障位置,其平均运行次数比传统相量函数得到的要小。在此基础上,分析了耦合电容式电压互感器(CCVT)对时域距离保护功能TD21安全性的影响,比较了其在兼顾主、次电压信号时的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Shift parameter sensitivity on the computation of unstable reduced order model via truncated balanced method Parametric sensitivity analysis of power transformer differential protection Busbar differential protection based on generalized alpha plane Traveling wave-based fault location formulation for hybrid lines with two sections Estimating the error between analytical and numerical finite difference solutions of laplace equation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1