Comparison of Relay Feedback Tuning and Other Tuning Methods for a Digitally Controlled Buck Converter

Ahmed Shehada, Yan Yan, A. R. Beig, I. Boiko
{"title":"Comparison of Relay Feedback Tuning and Other Tuning Methods for a Digitally Controlled Buck Converter","authors":"Ahmed Shehada, Yan Yan, A. R. Beig, I. Boiko","doi":"10.1109/IECON.2019.8926893","DOIUrl":null,"url":null,"abstract":"This paper presents a comparison between relay feedback tuning and other controller tuning methods for a digitally controlled DC-DC buck converter operating in continuous conduction mode. In the first method, a relay feedback test is used to obtain ultimate gain and period measurements experimentally. PI and PID controllers are then tuned according to the classic Ziegler-Nichols formulae. In the second and third method, a converter model is developed based on experimental identification and analytical derivation, respectively. PI and PID controllers are then designed through optimization of an integral performance criterion applied to the simulated step response. Experimental tests show that all three approaches to controller tuning provide comparable and acceptable results, but the simplicity of the approach based on the relay feedback test makes it a viable alternative to offline-tuned optimal controllers given the ability of the former to retune the controller to adapt to system changes. Results also suggest that with some improvements to the test and tuning rules, a well-tuned controller may be produced with reasonable computational effort in the auto-tuning schema.","PeriodicalId":187719,"journal":{"name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2019.8926893","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

This paper presents a comparison between relay feedback tuning and other controller tuning methods for a digitally controlled DC-DC buck converter operating in continuous conduction mode. In the first method, a relay feedback test is used to obtain ultimate gain and period measurements experimentally. PI and PID controllers are then tuned according to the classic Ziegler-Nichols formulae. In the second and third method, a converter model is developed based on experimental identification and analytical derivation, respectively. PI and PID controllers are then designed through optimization of an integral performance criterion applied to the simulated step response. Experimental tests show that all three approaches to controller tuning provide comparable and acceptable results, but the simplicity of the approach based on the relay feedback test makes it a viable alternative to offline-tuned optimal controllers given the ability of the former to retune the controller to adapt to system changes. Results also suggest that with some improvements to the test and tuning rules, a well-tuned controller may be produced with reasonable computational effort in the auto-tuning schema.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
数字控制Buck变换器继电器反馈调谐与其他调谐方法的比较
本文对工作在连续导通模式下的数字控制DC-DC降压变换器的继电器反馈整定与其他控制器整定方法进行了比较。在第一种方法中,使用继电器反馈测试来获得最终增益和周期的实验测量。然后根据经典的齐格勒-尼科尔斯公式对PI和PID控制器进行调谐。在第二种和第三种方法中,分别基于实验验证和解析推导建立了转炉模型。然后通过优化应用于模拟阶跃响应的积分性能准则来设计PI和PID控制器。实验测试表明,所有三种控制器调谐方法都提供了可比较和可接受的结果,但基于继电器反馈测试的方法的简单性使其成为离线调谐最优控制器的可行替代方案,因为前者能够重新调谐控制器以适应系统变化。结果还表明,通过对测试和调优规则进行一些改进,可以在自动调优模式下以合理的计算量产生良好的调优控制器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An Improved Lateral-coupling Thermal Impedance Model of a Half-Bridge Power Module under Inverter Operations A Brushless Synchronous Generator for Standalone DC Applications A New Method for Detecting Short-circuit Faults in Power Converter of Switched Reluctance Generator A Winding-based DC-Bus Capacitor Discharge Strategy for PMSM Drive System in EVs Considering Position Sensor Fault Historical Improvement Optimal Motion Planning with Model Predictive Trajectory Optimization for On-road Autonomous Vehicle
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1