{"title":"FAKTOR LINGKUNGAN FISIK YANG BERHUBUNGAN DENGAN ANGKA KUMAN UDARA DI RUANG RAWAT INAP KELAS I, II, DAN III RST WIJAYAKUSUMA PURWOKERTO TAHUN 2018","authors":"Citra Kusumawardhani U.P, A. Gunawan, Tri Cahyono","doi":"10.31983/KESLINGMAS.V38I2.4879","DOIUrl":null,"url":null,"abstract":"Hospital Is An Health Service Tool Which Is Possible Make A Healthcare Associated Infection (Hais) That Can Caused Of The Number Of Airborne Germs. Secondary Data Bacteriology Inspection Result Is point that the floor of 2nd class Srikandi Inpatient room is not full the condition, the result is 26 colony/cm2. The large of population is 67, while the large of sample is 35 sample. Analysis model that is used on this research is Rank Spearman. Data collection is done by measurement and observation. Mean of the measurement is, the number of airborne germs is 7871,43 CFU/m3, temperature is 27,35oC, humidity is 56,20%, lighting intensity is 154,63 lux, room density is 10,3 m2/TT. Analysis result for temperature and the number of airborne germs is p=0,465; (rho)=0,128, humidity with the number of airborne germs is p=0,828; (rho)=0,038, lighting intensity with the number of airborne germs is p=0,061; (rho)=0,320, density room with the number of airborne germs is p=0,885; (rho)=0,025, ventilation with the number of airborne germs is p=0,113; (rho)=0,273, means of air circulation with the number of airborne germs is p=0,636; (rho)=0,083.  All of factors of independent variable is not in significant relation with the number of airborne germs (p value 0,05). We recommend that routine desinfection every month to reduce the number of airborne germs","PeriodicalId":421886,"journal":{"name":"Buletin Keslingmas","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Buletin Keslingmas","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31983/KESLINGMAS.V38I2.4879","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Hospital Is An Health Service Tool Which Is Possible Make A Healthcare Associated Infection (Hais) That Can Caused Of The Number Of Airborne Germs. Secondary Data Bacteriology Inspection Result Is point that the floor of 2nd class Srikandi Inpatient room is not full the condition, the result is 26 colony/cm2. The large of population is 67, while the large of sample is 35 sample. Analysis model that is used on this research is Rank Spearman. Data collection is done by measurement and observation. Mean of the measurement is, the number of airborne germs is 7871,43 CFU/m3, temperature is 27,35oC, humidity is 56,20%, lighting intensity is 154,63 lux, room density is 10,3 m2/TT. Analysis result for temperature and the number of airborne germs is p=0,465; (rho)=0,128, humidity with the number of airborne germs is p=0,828; (rho)=0,038, lighting intensity with the number of airborne germs is p=0,061; (rho)=0,320, density room with the number of airborne germs is p=0,885; (rho)=0,025, ventilation with the number of airborne germs is p=0,113; (rho)=0,273, means of air circulation with the number of airborne germs is p=0,636; (rho)=0,083.  All of factors of independent variable is not in significant relation with the number of airborne germs (p value 0,05). We recommend that routine desinfection every month to reduce the number of airborne germs
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
2018年,与第一、二、三年级普劳克托病室空气细菌数量有关的物理环境因素
医院是一种卫生服务工具,有可能发生由空气中细菌数量引起的卫生保健相关感染。二级资料细菌学检查结果指出斯立坎地二级病房楼层不满,结果为26菌落/cm2。总体大数为67,样本大数为35。本研究使用的分析模型是Rank Spearman。数据收集是通过测量和观察完成的。测量的平均值为:空气细菌数7871.43 CFU/m3,温度27.35℃,湿度56.20%,光照强度154.63 lux,房间密度10.3 m2/TT。温度与空气细菌数分析结果p= 0.465;(rho)=0,128,湿度随空气细菌数p=0,828;(rho)= 0.038,光照强度随空气细菌数p= 0.061;(rho)=0,320,空气中细菌数量的密度室p=0,885;(rho)= 0.025,通风量随空气细菌数p= 0.113;(rho)=0,273,空气循环平均值与空气细菌数p=0,636;(ρ)= 0083。自变量各因素与空气细菌数无显著相关(p值为0.05)。我们建议每月进行常规消毒,以减少空气中细菌的数量
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Identifikasi Potensi Bahaya dan Upaya Pengendalian pada Proses Coal Hauling dan Coal Loading di Indonesia Evaluasi Sistem Pengelolaan Sampah Medis Padat di UPT Puskesmas Teluk Lingga Kabupaten Kutai Timur Hubungan antara Konstruksi Sumur Gali dan Jarak Sumber Pencemar dengan Kandungan Escherichia coli pada Sumur Gali Desa Pliken, Kecamatan Kembaran, Kabupaten Banyumas Tahun 2022 Pengaruh Variasi Bentuk Briket Sampah Serbuk Kayu terhadap Lama Waktu dalam Mencapai Titik Didih Air di Desa Bulakan Kecamatan Belik Kabupaten Pemalang Tahun 2023 Implementasi Pasar Tradisional Sehat di Kabupaten Banyumas dan Bagaimana Dampak dari Pandemi Covid 19
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1