{"title":"Antimony electrode for the determination of the intramyocardial pH during open-heart surgery.","authors":"Y Ota,&nbsp;M Tsunemoto,&nbsp;M Shimada","doi":"10.1088/0143-0815/13/4/004","DOIUrl":null,"url":null,"abstract":"<p><p>The development of an antiomony electrode (Sb) and a pH meter as a substitute for a glass electrode(G) to measure the intramyocardial pH is reported, and the results of their clinical application. The determination of the pH of CPD (citrate-phosphate-dextrose) blood by Sb showed small differences when compared to G (less than 0.1). Sb was also temperature sensitive. The temperature coefficient of Sb was determined in buffers by varying their temperatures, and an antimony-thermocouple electrode and a temperature-compensated pH meter were subsequently constructed. In CPD blood of varying temperatures Sb showed similar tendencies to G. The results of the application of the new apparatus to 28 patients were statistically no different from those obtained previously by G on 22 patients, either in baseline pH or its fall following aortic cross-clamping. It is concluded that although Sb is not as accurate as G, it is a reasonable alternative for the determination of myocardial acidosis during open-heart surgery.</p>","PeriodicalId":77070,"journal":{"name":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","volume":"13 4","pages":"335-47"},"PeriodicalIF":0.0000,"publicationDate":"1992-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0143-0815/13/4/004","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0143-0815/13/4/004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The development of an antiomony electrode (Sb) and a pH meter as a substitute for a glass electrode(G) to measure the intramyocardial pH is reported, and the results of their clinical application. The determination of the pH of CPD (citrate-phosphate-dextrose) blood by Sb showed small differences when compared to G (less than 0.1). Sb was also temperature sensitive. The temperature coefficient of Sb was determined in buffers by varying their temperatures, and an antimony-thermocouple electrode and a temperature-compensated pH meter were subsequently constructed. In CPD blood of varying temperatures Sb showed similar tendencies to G. The results of the application of the new apparatus to 28 patients were statistically no different from those obtained previously by G on 22 patients, either in baseline pH or its fall following aortic cross-clamping. It is concluded that although Sb is not as accurate as G, it is a reasonable alternative for the determination of myocardial acidosis during open-heart surgery.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
心内直视手术中测定心内pH值的锑电极。
本文报道了一种锑电极(Sb)和pH计代替玻璃电极(G)测量心内pH值的发展及其临床应用结果。Sb测定CPD(柠檬酸盐-磷酸盐-葡萄糖)血pH值与G比较差异不大(小于0.1)。某人对温度也很敏感。通过改变缓冲液的温度来测定Sb的温度系数,并构建了锑热电偶电极和温度补偿pH计。在不同温度的CPD血液中,Sb表现出与G相似的趋势。在28例患者中应用新仪器的结果与G先前在22例患者中获得的结果在统计学上没有差异,无论是基线pH还是主动脉交叉夹夹后pH的下降。综上所述,Sb虽不如G准确,但可作为心内直视手术中心肌酸中毒的一种合理选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measurement of surgical diathermy current during trans-urethral resection of the prostate gland. Flow measurement using duplex Doppler ultrasound: haemodynamic changes in patients with colorectal liver metastases. A thermal clearance probe for continuous monitoring of cerebral blood flow. Antimony electrode for the determination of the intramyocardial pH during open-heart surgery. Spectrophotometric measurements of haemoglobin saturation and concentration in skin during the tuberculin reaction in normal human subjects.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1