{"title":"Development of the micro capillary pumped loop for electronic cooling","authors":"Seok-Hwan Moon, G. Hwang","doi":"10.1109/THERMINIC.2007.4451750","DOIUrl":null,"url":null,"abstract":"Electronic devices have been minimized but the performance of those is becoming better and better. Therefore it is needed to develop new cooling methods suitable for a thin packaging structure with high thermal density. The thin flat plate type micro CPL(capillary pumped loop) with the thickness less than 2 mm was developed in this study. The proposed micro CPL has two staged grooves in evaporator instead of poles for preventing backflows of the vapor bubble and the simpler structure than that of a micro CPL with the poles. Also a large vapor space from the evaporator to the condenser was constructed in the middle plate therefore flow resistance of the vapor could be reduced. The micro CPL was fabricated using MEMS technology. The micro CPL was composed of lower, middle and upper substrates. The lower substrate was made of silicon and the middle and upper substrates are made of Pyrex glass for visualization. Through a preliminary test it was checked that there was no leakage at the adhesion interface between lower and middle or upper substrates and at the bonding interface between lower substrate and fill tube. Although the experimental studies for the micro CPL have been poor till now, we have obtained the reasonable experimental results in this study. The performance test result has showed 8.5 W of the heat transfer rate for the micro CPL and we could observe the operating characteristics of circulating or evaporating and condensing by visualization. Pure distilled water was used as the working fluid.","PeriodicalId":264943,"journal":{"name":"2007 13th International Workshop on Thermal Investigation of ICs and Systems (THERMINIC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 13th International Workshop on Thermal Investigation of ICs and Systems (THERMINIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/THERMINIC.2007.4451750","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Electronic devices have been minimized but the performance of those is becoming better and better. Therefore it is needed to develop new cooling methods suitable for a thin packaging structure with high thermal density. The thin flat plate type micro CPL(capillary pumped loop) with the thickness less than 2 mm was developed in this study. The proposed micro CPL has two staged grooves in evaporator instead of poles for preventing backflows of the vapor bubble and the simpler structure than that of a micro CPL with the poles. Also a large vapor space from the evaporator to the condenser was constructed in the middle plate therefore flow resistance of the vapor could be reduced. The micro CPL was fabricated using MEMS technology. The micro CPL was composed of lower, middle and upper substrates. The lower substrate was made of silicon and the middle and upper substrates are made of Pyrex glass for visualization. Through a preliminary test it was checked that there was no leakage at the adhesion interface between lower and middle or upper substrates and at the bonding interface between lower substrate and fill tube. Although the experimental studies for the micro CPL have been poor till now, we have obtained the reasonable experimental results in this study. The performance test result has showed 8.5 W of the heat transfer rate for the micro CPL and we could observe the operating characteristics of circulating or evaporating and condensing by visualization. Pure distilled water was used as the working fluid.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电子冷却用微毛细管泵浦回路的研制
电子设备已经被最小化,但它们的性能却变得越来越好。因此,需要开发适合高热密度薄封装结构的新型冷却方法。研制了厚度小于2 mm的薄板型微型毛细管泵浦袢(CPL)。本文提出的微型CPL在蒸发器内采用两段槽来代替极来防止汽泡回流,其结构比带极的微型CPL更简单。在中间板上构造了从蒸发器到冷凝器的较大的蒸汽空间,从而减小了蒸汽的流动阻力。采用MEMS技术制备微CPL。微CPL由下基片、中基片和上基片组成。下部衬底由硅制成,中间和上部衬底由耐热玻璃制成,以便可视化。通过初步试验,检查下基材与中、上基材的粘结界面、下基材与填充管的粘结界面均无泄漏。虽然目前对微CPL的实验研究还比较贫乏,但我们在本研究中获得了合理的实验结果。性能试验结果表明,微型CPL的换热速率为8.5 W,可以直观地观察到循环或蒸发冷凝的运行特性。工作液采用纯蒸馏水。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation technique for the failure life scatter of lead-free solder joints in electronic device Vibration combined high Temperature Cycle Tests for capacitive MEMS accelerometers New reliability assessment method for solder joints in BGA package by considering the interaction between design factors Development of a prototype thermal management solution for 3-D stacked chip electronics by interleaved solid spreaders and synthetic jets Influence of transparent surface layer on effective thermoreflectance coefficient of typical stacked electronic structures
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1