Specific Harmonic Power Suppression of Drector-Power-Controlled Current-Source PWM Rectifier

T. Noguchi, K. Sano
{"title":"Specific Harmonic Power Suppression of Drector-Power-Controlled Current-Source PWM Rectifier","authors":"T. Noguchi, K. Sano","doi":"10.1109/PEDS.2007.4487893","DOIUrl":null,"url":null,"abstract":"This paper focuses on specific harmonic active power suppression of a direct-power-controlled (DPC) PWM current-source rectifier (CSR) in order to achieve low distortion of the input line currents. Total input power factor of the DPC-based PWMCSR becomes worse as the load gets lower due to the low-order harmonics in the line currents, especially the fifth and the seventh. Since the dominant low-order harmonic currents cause an oscillation in the active power at frequency of sixth, suppression of the sixth-order harmonic active power is essential to improve the total power factor particularly in the low-load range. The paper describes a theoretical aspect and a suppression technique of the harmonic active power, followed by basic configuration and operation of the DPC-based PWMCSR. Effectiveness of the proposed technique is confirmed through computer simulations and experimental tests, using a 2-kW prototype. As a result, the total harmonic distortion of the line currents is effectively reduced by 10 %, which results in approximately 20-% improvement of the total input power factor at a 350-W load condition.","PeriodicalId":166704,"journal":{"name":"2007 7th International Conference on Power Electronics and Drive Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 7th International Conference on Power Electronics and Drive Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.2007.4487893","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

This paper focuses on specific harmonic active power suppression of a direct-power-controlled (DPC) PWM current-source rectifier (CSR) in order to achieve low distortion of the input line currents. Total input power factor of the DPC-based PWMCSR becomes worse as the load gets lower due to the low-order harmonics in the line currents, especially the fifth and the seventh. Since the dominant low-order harmonic currents cause an oscillation in the active power at frequency of sixth, suppression of the sixth-order harmonic active power is essential to improve the total power factor particularly in the low-load range. The paper describes a theoretical aspect and a suppression technique of the harmonic active power, followed by basic configuration and operation of the DPC-based PWMCSR. Effectiveness of the proposed technique is confirmed through computer simulations and experimental tests, using a 2-kW prototype. As a result, the total harmonic distortion of the line currents is effectively reduced by 10 %, which results in approximately 20-% improvement of the total input power factor at a 350-W load condition.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
功率控制电流源型PWM整流器的谐波功率抑制
本文主要研究直接功率控制(DPC) PWM电流源整流器(CSR)的特定谐波有功功率抑制,以实现输入线路电流的低失真。由于线路电流中的低次谐波,特别是五次和七次谐波,当负载降低时,基于dpc的PWMCSR的总输入功率因数会变差。由于占主导地位的低阶谐波电流会在频率为6的有功功率中引起振荡,因此抑制六阶谐波有功功率对于提高总功率因数至关重要,特别是在低负荷范围内。本文介绍了谐波有功功率的理论和抑制技术,以及基于dpc的PWMCSR的基本结构和工作原理。采用2kw样机,通过计算机模拟和实验测试,验证了该技术的有效性。因此,在350w负载条件下,线路电流的总谐波失真有效降低了10%,从而使总输入功率因数提高了约20%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Application of Multi-level Multi-domain Modeling in the Design and Analysis of a PM Transverse Flux Motor with SMC Core An Analytic Approach To Harmonic Analysis of 48-Pulse Voltage Source Inverter Combined System of Static Synchronous Series Compensation and Passive Filter applied to Wind Energy Conversion System Speed Sensorless Control with Neuron MRAS Estimator of an Induction Machine Nonlinear Decoupled Control for a Six-Phase Series-Connected Two Induction Motor Drive Using the Sliding-Mode Technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1