{"title":"Load frequency control of multi-microgrid using energy storage system","authors":"A. Chowdhury, Md. Asaduz-Zaman","doi":"10.1109/ICECE.2014.7026975","DOIUrl":null,"url":null,"abstract":"Control of active power and frequency in a power system is referred to as load frequency control (LFC). A linear combination of tie line power between interconnected system and frequency deviations, defined as area control error (ACE), is regulated to zero by LFC such that frequency and tie-line power errors are forced to zeros and a balance is achieved between generation and load. This paper presents an investigation on the LFC of multi-microgrid (MMG) using energy storage system (ESS). The tie-line connected MMG system consists of two microgrids, each made up of a synchronous generator, a PV source, a wind power system, ESS and load. Control strategies are developed based on both, frequency deviation and ACE, to regulate the ESS output. A performance index is defined for comparative assessment of control strategies. Effectiveness of the frequency control strategies is studied through simulation.","PeriodicalId":335492,"journal":{"name":"8th International Conference on Electrical and Computer Engineering","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"8th International Conference on Electrical and Computer Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECE.2014.7026975","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30
Abstract
Control of active power and frequency in a power system is referred to as load frequency control (LFC). A linear combination of tie line power between interconnected system and frequency deviations, defined as area control error (ACE), is regulated to zero by LFC such that frequency and tie-line power errors are forced to zeros and a balance is achieved between generation and load. This paper presents an investigation on the LFC of multi-microgrid (MMG) using energy storage system (ESS). The tie-line connected MMG system consists of two microgrids, each made up of a synchronous generator, a PV source, a wind power system, ESS and load. Control strategies are developed based on both, frequency deviation and ACE, to regulate the ESS output. A performance index is defined for comparative assessment of control strategies. Effectiveness of the frequency control strategies is studied through simulation.