{"title":"STATCOM Control for Operation with Unbalanced Voltages","authors":"B. Blazic, I. Papič","doi":"10.1109/EPEPEMC.2006.4778608","DOIUrl":null,"url":null,"abstract":"In view of STATCOM operation analysis, special attention must be paid to the operation with unbalanced network voltages. In this paper a control algorithm that enables STATCOM operation with unbalanced voltages is presented. The algorithm is based on the compensator mathematical model in the d-q coordinate system. In case of an unbalanced voltage sag the compensator unbalances the generated voltages to limit the negative sequence currents. The problem of low-order harmonics generation is solved with the use of appropriate switching function modulation that enables the use of a relatively small capacitor on the DC side. The proposed algorithm was tested by means of simulation of STATCOM operation in the PSCAD program. The algorithm shows a good transient response also in the case of relatively deep voltage sags","PeriodicalId":401288,"journal":{"name":"2006 12th International Power Electronics and Motion Control Conference","volume":"112 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 12th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEPEMC.2006.4778608","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
Abstract
In view of STATCOM operation analysis, special attention must be paid to the operation with unbalanced network voltages. In this paper a control algorithm that enables STATCOM operation with unbalanced voltages is presented. The algorithm is based on the compensator mathematical model in the d-q coordinate system. In case of an unbalanced voltage sag the compensator unbalances the generated voltages to limit the negative sequence currents. The problem of low-order harmonics generation is solved with the use of appropriate switching function modulation that enables the use of a relatively small capacitor on the DC side. The proposed algorithm was tested by means of simulation of STATCOM operation in the PSCAD program. The algorithm shows a good transient response also in the case of relatively deep voltage sags