PC-based real-time control system for power-electronic test benches with high I/O requirements

M. Spichartz, V. Staudt, A. Steimel
{"title":"PC-based real-time control system for power-electronic test benches with high I/O requirements","authors":"M. Spichartz, V. Staudt, A. Steimel","doi":"10.1109/POWERENG.2011.6036475","DOIUrl":null,"url":null,"abstract":"The control of power-electronic laboratory test benches for academic use and for industrial research and development demands a real-time control system with high flexibility and reliability at low cost. Personal computers are an ideal basis for this kind of real-time control systems because of their high processing power at very low cost and their expandability by additional interface cards. An additional field-programmable gate array is necessary to assure the real-time ability by defining the equidistant hard real-time task including the measurement routines, the control calculations and the switching signals output. The presented control system is optimized for the use in a Modular Multilevel Converter test bench, designed as a five-level converter with a high number of inputs and outputs.","PeriodicalId":166144,"journal":{"name":"2011 International Conference on Power Engineering, Energy and Electrical Drives","volume":"150 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2011.6036475","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

The control of power-electronic laboratory test benches for academic use and for industrial research and development demands a real-time control system with high flexibility and reliability at low cost. Personal computers are an ideal basis for this kind of real-time control systems because of their high processing power at very low cost and their expandability by additional interface cards. An additional field-programmable gate array is necessary to assure the real-time ability by defining the equidistant hard real-time task including the measurement routines, the control calculations and the switching signals output. The presented control system is optimized for the use in a Modular Multilevel Converter test bench, designed as a five-level converter with a high number of inputs and outputs.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于pc的高I/O电力电子试验台实时控制系统
用于学术研究和工业研发的电力电子实验室试验台的控制需要一个高灵活性、高可靠性、低成本的实时控制系统。个人计算机是这种实时控制系统的理想基础,因为它们的高处理能力和极低的成本以及通过附加接口卡的可扩展性。通过定义等距硬实时任务,包括测量例程、控制计算和开关信号输出,需要额外的现场可编程门阵列来确保实时性。所提出的控制系统针对模块化多电平变换器试验台进行了优化,该试验台设计为具有大量输入和输出的五电平变换器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Low cost DC lines PLC based photovoltaic plants parameters smart monitoring communications and control module Smart meters for distributed filtering of high harmonics in Smart Grid FPGA controller for power converters with integrated oscilloscope and graphical user interface On the square arc voltage waveform model in magnetic discharge lamp studies Interplay of Smart Grids and Intelligent Systems and Control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1