Automatic realignment of myocardial first-pass MR perfusion images

A. Comte, A. Lalande, F. Brunotte
{"title":"Automatic realignment of myocardial first-pass MR perfusion images","authors":"A. Comte, A. Lalande, F. Brunotte","doi":"10.1109/ISPA.2003.1296367","DOIUrl":null,"url":null,"abstract":"Magnetic resonance first-pass imaging of a bolus of contrast agent is well adapted to distinguish normal and hypoperfused areas of the myocardium. In most cases, the signal intensity-time curves in user defined regions of interest (ROI) are studied. As image acquisition is ECG-gated, the images are acquired at the same moment in the cardiac cycle, and the basic shape of the heart is similar from one view to the next. However, superficial respiratory motion can displace the heart in the short-axis plane. The aim of this study is to correct for the respiratory motion of the heart by performing an automatic realignment of the myocardial ROI based on a method tracking the movement of the lung-myocardium interface. Visual and quantitative analyses performed on 120 curves show a very good concordance between the automatic methods and the manual one.","PeriodicalId":218932,"journal":{"name":"3rd International Symposium on Image and Signal Processing and Analysis, 2003. ISPA 2003. Proceedings of the","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"3rd International Symposium on Image and Signal Processing and Analysis, 2003. ISPA 2003. Proceedings of the","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPA.2003.1296367","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Magnetic resonance first-pass imaging of a bolus of contrast agent is well adapted to distinguish normal and hypoperfused areas of the myocardium. In most cases, the signal intensity-time curves in user defined regions of interest (ROI) are studied. As image acquisition is ECG-gated, the images are acquired at the same moment in the cardiac cycle, and the basic shape of the heart is similar from one view to the next. However, superficial respiratory motion can displace the heart in the short-axis plane. The aim of this study is to correct for the respiratory motion of the heart by performing an automatic realignment of the myocardial ROI based on a method tracking the movement of the lung-myocardium interface. Visual and quantitative analyses performed on 120 curves show a very good concordance between the automatic methods and the manual one.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
心肌首过MR灌注图像的自动调整
一剂造影剂的第一次磁共振成像可以很好地区分心肌的正常和低灌注区域。在大多数情况下,研究用户定义的感兴趣区域(ROI)中的信号强度-时间曲线。由于图像采集是ecg门控的,因此图像是在心脏周期的同一时刻采集的,并且从一个视图到下一个视图的心脏基本形状是相似的。然而,浅呼吸运动可使心脏在短轴平面上移位。本研究的目的是通过基于跟踪肺-心肌界面运动的方法对心肌ROI进行自动调整来纠正心脏的呼吸运动。对120条曲线进行的目视和定量分析表明,自动方法与人工方法具有很好的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Learning semantics in content based image retrieval Timing-free blind multiuser detection for multicarrier DS/CDMA systems with multiple antennas Adaptive weighted median filter using local entropy for ultrasonic image denoising A new 2D adaptive nonlinear filter based on the Lyapunov stability theory Tissue segmentation of multi-channel brain images with inhomogeneity correction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1