EMG Bandwidth used in Signal Whitening

Meera Dasog, Kishor Koirala, Pu Liu, E. Clancy
{"title":"EMG Bandwidth used in Signal Whitening","authors":"Meera Dasog, Kishor Koirala, Pu Liu, E. Clancy","doi":"10.1109/NEBEC.2013.87","DOIUrl":null,"url":null,"abstract":"It has been demonstrated that whitening the surface electromyogram (EMG) improves EMG amplitude (EMGσ) estimation. But, due to the wide bandwidth ranges often used when whitening, custom high-cost electrodes (bandwidth of ~2000 Hz) have been used. This paper investigates the effect of limiting the bandwidth for the whitened EMG data. The change in the average error of EMG to torque estimation was observed for 54 subjects over different whitening bandwidths ranging from 20-2000 Hz. We found that the average error remained the same for bandwidth limits between 600 Hz to 2000 Hz, suggesting that wider EMG electrodes were not helpful with this data set.","PeriodicalId":153112,"journal":{"name":"2013 39th Annual Northeast Bioengineering Conference","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 39th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBEC.2013.87","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

It has been demonstrated that whitening the surface electromyogram (EMG) improves EMG amplitude (EMGσ) estimation. But, due to the wide bandwidth ranges often used when whitening, custom high-cost electrodes (bandwidth of ~2000 Hz) have been used. This paper investigates the effect of limiting the bandwidth for the whitened EMG data. The change in the average error of EMG to torque estimation was observed for 54 subjects over different whitening bandwidths ranging from 20-2000 Hz. We found that the average error remained the same for bandwidth limits between 600 Hz to 2000 Hz, suggesting that wider EMG electrodes were not helpful with this data set.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
信号白化中肌电信号带宽的应用
研究表明,表面肌电白化可以改善肌电振幅(EMGσ)的估计。但是,由于美白时经常使用的带宽范围很宽,因此使用了定制的高成本电极(带宽为~2000 Hz)。本文研究了限制带宽对白化肌电图数据的影响。观察了54名受试者在20 ~ 2000 Hz不同白化带宽下肌电图对转矩估计的平均误差变化。我们发现,在600 Hz到2000 Hz的带宽范围内,平均误差保持不变,这表明更宽的肌电电极对该数据集没有帮助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison between T2 Relaxation Time and Storage Modulus for Agarose Gel The Electroencephalographic Response during a Driving Process: Normal Driving, Turning and Collision Biocompatibility of CaO-Na2O-SiO2/TiO2 Glass Ceramic Scaffolds for Orthopaedic Applications Improvement on Dental Ceramics Using Microwave Sintering Influence of Eccentric Loading and Size of Implant Fixture on the Stress Distribution in the Implant
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1