An Optimal PMU Placement Against N-1 Contingency of PMU Using Integer Linear Programming Approach

Muhammad Musadiq Ahmed, K. Imran
{"title":"An Optimal PMU Placement Against N-1 Contingency of PMU Using Integer Linear Programming Approach","authors":"Muhammad Musadiq Ahmed, K. Imran","doi":"10.1109/ICAEM.2019.8853656","DOIUrl":null,"url":null,"abstract":"Phasor Measurement Unit is a time synchronized metering device that gives very fast and accurate data of voltage and current magnitudes and angles for monitoring and control of power system. As cost of PMU procurement and installation is high, optimal placement of PMUs is critical. In this paper, Binary Integer Linear Programming is used to find optimal locations of PMUs for complete system observability under N-1 PMU contingency. The placement algorithm is tested on seven test bed systems. Optimal Placement Problem is formulated for New England 39 Bus system. Results are also verified for IEEE 14, 30, 57, 118, 145 and Polish 2383 bus systems. The simulation results show that the proposed algorithm gives the optimal location of PMUs in the power system by keeping complete system observable.","PeriodicalId":304208,"journal":{"name":"2019 International Conference on Applied and Engineering Mathematics (ICAEM)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Applied and Engineering Mathematics (ICAEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAEM.2019.8853656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Phasor Measurement Unit is a time synchronized metering device that gives very fast and accurate data of voltage and current magnitudes and angles for monitoring and control of power system. As cost of PMU procurement and installation is high, optimal placement of PMUs is critical. In this paper, Binary Integer Linear Programming is used to find optimal locations of PMUs for complete system observability under N-1 PMU contingency. The placement algorithm is tested on seven test bed systems. Optimal Placement Problem is formulated for New England 39 Bus system. Results are also verified for IEEE 14, 30, 57, 118, 145 and Polish 2383 bus systems. The simulation results show that the proposed algorithm gives the optimal location of PMUs in the power system by keeping complete system observable.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于整数线性规划方法的PMU N-1偶然性最优布局
相量测量装置是一种时间同步测量装置,它可以提供非常快速和准确的电压和电流的大小和角度数据,用于电力系统的监测和控制。由于PMU的采购和安装成本很高,因此PMU的最佳放置至关重要。在N-1 PMU偶然性条件下,利用二元整数线性规划方法求解系统完全可观测PMU的最优位置。该算法在7个试验台系统上进行了测试。提出了新英格兰39公交系统的最优布局问题。结果也验证了IEEE 14、30、57、118、145和波兰2383总线系统。仿真结果表明,该算法在保持系统完全可观测的情况下,给出了pmu在电力系统中的最优位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
2019 International Conference on Applied and Engineering Mathematics (ICAEM) Crowd Counting with respect to Age and Gender by using Faster R-CNN based Detection Acoustic and Electromagnetic Effective Medium Properties of Fano Resonant Metamaterials ICAEM Organizing Committee Microsoft Word Forensic Artifacts in Windows 10 Registry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1