The effects of different body positions on the accuracy of ultra-short-term heart rate variability indexes

Q1 Business, Management and Accounting Journal of High Technology Management Research Pub Date : 2020-05-01 DOI:10.1016/j.hitech.2020.100375
Clifton J. Holmes , Michael V. Fedewa , Ward C. Dobbs , Yuan Liu , Andrew A. Flatt , Fabio Y. Nakamura , Michael R. Esco
{"title":"The effects of different body positions on the accuracy of ultra-short-term heart rate variability indexes","authors":"Clifton J. Holmes ,&nbsp;Michael V. Fedewa ,&nbsp;Ward C. Dobbs ,&nbsp;Yuan Liu ,&nbsp;Andrew A. Flatt ,&nbsp;Fabio Y. Nakamura ,&nbsp;Michael R. Esco","doi":"10.1016/j.hitech.2020.100375","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>With the increasing popularity of ultra-short heart rate variability (HRV) measurements being utilized with mobile devices outside of controlled, research settings, it is important to determine the proper methodology to ensure accuracy. Therefore, the purpose of this study was to examine the validity of ultra-short-term HRV metrics across three different body positions in recreationally active individuals.</p></div><div><h3>Methods</h3><p>Twenty-six subjects (12 males: 24.1 ± 3.6 yrs., 178.6 ± 6.4 cm, 82.9 ± 8.7 kg; 15 females: 21.3 ± 1.2 yrs., 170.7 ± 10.5 cm, 71.6 ± 18.9 kg) participated in 10-min electrocardiogram recordings in the supine, seated, and standing positions. HRV analysis using a variety of time, frequency, and non-linear parameters were performed following traditional recommendations (i.e., last 5 min of each 10-min recording) and ultra-short-term recordings (i.e., 1-min epoch following a 1-min stabilization period).</p></div><div><h3>Results</h3><p>Slight decreases (e.g., “near perfect” to “very large”) in intraclass correlations (ICC) and increases in the limits of agreement (LOA) were noted for most of the HRV metrics as position changed to sitting and then standing. However, throughout all three positions, the highest ICC values (0.88 to 0.92) and tightest LOA (CE ± 1.96 SD) were displayed in RMSSD.</p></div><div><h3>Conclusions</h3><p>This study supports the use of RMSSD and SD1 for assessing HRV under ultra-short-term recordings of 1 min regardless of position. However, practitioners should be consistent with the preferred position for measurements and not use them interchangeably to reduce potential errors during long-term monitoring.</p></div>","PeriodicalId":38944,"journal":{"name":"Journal of High Technology Management Research","volume":"31 1","pages":"Article 100375"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.hitech.2020.100375","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of High Technology Management Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1047831020300067","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Business, Management and Accounting","Score":null,"Total":0}
引用次数: 9

Abstract

Purpose

With the increasing popularity of ultra-short heart rate variability (HRV) measurements being utilized with mobile devices outside of controlled, research settings, it is important to determine the proper methodology to ensure accuracy. Therefore, the purpose of this study was to examine the validity of ultra-short-term HRV metrics across three different body positions in recreationally active individuals.

Methods

Twenty-six subjects (12 males: 24.1 ± 3.6 yrs., 178.6 ± 6.4 cm, 82.9 ± 8.7 kg; 15 females: 21.3 ± 1.2 yrs., 170.7 ± 10.5 cm, 71.6 ± 18.9 kg) participated in 10-min electrocardiogram recordings in the supine, seated, and standing positions. HRV analysis using a variety of time, frequency, and non-linear parameters were performed following traditional recommendations (i.e., last 5 min of each 10-min recording) and ultra-short-term recordings (i.e., 1-min epoch following a 1-min stabilization period).

Results

Slight decreases (e.g., “near perfect” to “very large”) in intraclass correlations (ICC) and increases in the limits of agreement (LOA) were noted for most of the HRV metrics as position changed to sitting and then standing. However, throughout all three positions, the highest ICC values (0.88 to 0.92) and tightest LOA (CE ± 1.96 SD) were displayed in RMSSD.

Conclusions

This study supports the use of RMSSD and SD1 for assessing HRV under ultra-short-term recordings of 1 min regardless of position. However, practitioners should be consistent with the preferred position for measurements and not use them interchangeably to reduce potential errors during long-term monitoring.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同体位对超短期心率变异性指标准确性的影响
随着超短心率变异性(HRV)测量在受控研究环境之外的移动设备上的日益普及,确定适当的方法以确保准确性非常重要。因此,本研究的目的是检验三种不同体位的娱乐性运动个体的超短期HRV指标的有效性。方法男性12例,年龄24.1±3.6岁。, 178.6±6.4 cm, 82.9±8.7 kg;女性15例:21.3±1.2岁。(170.7±10.5 cm, 71.6±18.9 kg),分别以仰卧位、坐位和站立位参与10分钟心电图记录。使用各种时间、频率和非线性参数进行HRV分析,按照传统建议(即每10分钟记录的最后5分钟)和超短期记录(即1分钟稳定期后1分钟epoch)进行。结果:当体位改变为坐着,然后站着时,大多数HRV指标的类内相关性(ICC)轻微下降(例如,从“接近完美”到“非常大”),一致性极限(LOA)增加。然而,在所有三个位置中,RMSSD显示的ICC值最高(0.88至0.92)和LOA最小(CE±1.96 SD)。本研究支持使用RMSSD和SD1在1分钟的超短期记录下评估HRV,无论位置如何。然而,从业者应该与测量的首选位置保持一致,而不是互换使用它们,以减少长期监测期间潜在的错误。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of High Technology Management Research
Journal of High Technology Management Research Business, Management and Accounting-Strategy and Management
CiteScore
5.80
自引率
0.00%
发文量
9
审稿时长
62 days
期刊介绍: The Journal of High Technology Management Research promotes interdisciplinary research regarding the special problems and opportunities related to the management of emerging technologies. It advances the theoretical base of knowledge available to both academicians and practitioners in studying the management of technological products, services, and companies. The Journal is intended as an outlet for individuals conducting research on high technology management at both a micro and macro level of analysis.
期刊最新文献
Editorial Board Corrigendum to “AI in public-private partnership for IT infrastructure development” [The Journal of High Technology Management Research 35 (2024) 1–10/100496] Examining the impact of artificial intelligence on employee performance in the digital era: An analysis and future research direction You will never stand alone: The role of inter-organizational collaboration and technological turbulence in shaping small business' digital maturity Digital transformational leadership and organizational agility in digital transformation: Structural equation modelling of the moderating effects of digital culture and digital strategy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1