STRENGTHENING OF FIRE DAMAGED REINFORCED CONCRETE COLUMNS USING FERROCEMENT

A. Bari, A. Amin, R. Riyad, Md. Lutfar Rahman Talukder
{"title":"STRENGTHENING OF FIRE DAMAGED REINFORCED CONCRETE COLUMNS USING FERROCEMENT","authors":"A. Bari, A. Amin, R. Riyad, Md. Lutfar Rahman Talukder","doi":"10.11113/mjce.v33.17495","DOIUrl":null,"url":null,"abstract":"A number of things, like extreme loading and severe environmental exposures, can cause the deterioration of ferroconcrete Reinforced Concrete columns. Ferrocement is currently used as a part of the well-liked method for extending the lifetime of a deteriorated column. The appliance of Ferrocement is restricted to the strengthening of loaded RC columns which have been broken by fire. Depending on the fire’s intensity (duration and temperature), the exposure of an RC column to a fireplace may result in a reduction in the strength of the column during both the heating and cooling periods. The utilization of Ferrocement is often effective in restoring the strength of the column, although it'll require careful protection to protect against heating in the future. This research concerns the effectiveness of using Ferrocement confinement to repair RC columns damaged by fire. The effectiveness of confinement is set by comparing the behaviors of retrofitted, controlled, and fire damaged specimens. Locally available materials like steel wire mesh as a neighborhood of Ferrocement confinement have been utilized in this study because of the confining materials. For this purpose, six rectangular short columns with a dimension of 150 mm × 150 mm × 800 mm have been cast and tested. The residual behavior of the columns after being retrofitted is evaluated and compared against that of the control columns. The test results show that the effect of confinement has been evaluated by comparing the results with unconfined and fire damaged specimens. The load capacity of the columns has decreased by about 46 % after the fire damage. Further the capacity is increased by 23% and 49% using Ferro cement confinement with one layer and two layer respectively.","PeriodicalId":429144,"journal":{"name":"Malaysian Journal of Civil Engineering","volume":"2008 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malaysian Journal of Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11113/mjce.v33.17495","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A number of things, like extreme loading and severe environmental exposures, can cause the deterioration of ferroconcrete Reinforced Concrete columns. Ferrocement is currently used as a part of the well-liked method for extending the lifetime of a deteriorated column. The appliance of Ferrocement is restricted to the strengthening of loaded RC columns which have been broken by fire. Depending on the fire’s intensity (duration and temperature), the exposure of an RC column to a fireplace may result in a reduction in the strength of the column during both the heating and cooling periods. The utilization of Ferrocement is often effective in restoring the strength of the column, although it'll require careful protection to protect against heating in the future. This research concerns the effectiveness of using Ferrocement confinement to repair RC columns damaged by fire. The effectiveness of confinement is set by comparing the behaviors of retrofitted, controlled, and fire damaged specimens. Locally available materials like steel wire mesh as a neighborhood of Ferrocement confinement have been utilized in this study because of the confining materials. For this purpose, six rectangular short columns with a dimension of 150 mm × 150 mm × 800 mm have been cast and tested. The residual behavior of the columns after being retrofitted is evaluated and compared against that of the control columns. The test results show that the effect of confinement has been evaluated by comparing the results with unconfined and fire damaged specimens. The load capacity of the columns has decreased by about 46 % after the fire damage. Further the capacity is increased by 23% and 49% using Ferro cement confinement with one layer and two layer respectively.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
火损钢筋混凝土柱的铁浆加固
许多事情,如极端载荷和恶劣的环境暴露,会导致钢筋混凝土柱的恶化。加固是目前常用的延长老化柱寿命的方法之一。钢筋混凝土的应用仅限于加固受火破坏的钢筋混凝土柱。根据火灾的强度(持续时间和温度),RC柱暴露在壁炉中可能导致柱在加热和冷却期间的强度降低。铁水泥的使用通常有效地恢复了柱的强度,尽管它需要仔细保护,以防止将来加热。本文研究了钢筋混凝土柱火灾破坏后,采用钢筋混凝土约束修复的有效性。通过比较改造、控制和火灾破坏试件的行为来确定约束的有效性。由于约束材料的原因,本研究中使用了当地可用的材料,如钢丝网作为Ferrocement约束的邻居。为此,对6根尺寸为150mm × 150mm × 800mm的矩形短柱进行浇铸和试验。改造后的柱的残余行为进行了评估,并与对照柱进行了比较。试验结果表明,通过与无约束和火灾破坏试件的对比,可以评价约束的影响。火灾破坏后,柱的承载能力下降了约46%。此外,采用一层和两层铁水泥约束,容量分别提高了23%和49%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
THE IMPLEMENTATION OF INTEGRATED MANAGEMENT SYSTEMS (IMS) IN CONSTRUCTION ORGANIZATIONS IN MALAYSIA STUDY OF THE PERFORMANCE OF WASTE PLASTIC IN CLAY SOIL STABILIZATION COMPARATIVE ANALYSIS OF PORTLAND AND WHITE CEMENT IMPACT ON UNCONFINED COMPRESSIVE STRENGTH OF SOIL VIBRATION-BASED DAMAGE DETECTION FOR ONE-STORY STEEL FRAME STRUCTURE USING MODE SHAPE CURVATURE PREDICTING GEOTECHNICAL AXIAL CAPACITY OF REINFORCED CONCRETE DRIVEN PILE USING MACHINE LEARNING TECHNIQUE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1